Air Shutter Adjustment (oven burner only)

The quality of the flame can be changed by adjusting the air shutters. Factory setting on the air shutter is 0.40" (10.6mm). (see figure 29)

Reduce the shutter opening if:

 

• the flame appears unsteady

 

• is not burning all the way around

 

• is noisy like a small blow torch.

 

Increase the shutter opening if:

 

• the flame has yellow tips

 

• there is no sharp blue cone

 

• soot appears on the bottom of cooking pans.

air shutter adjustment

 

 

Figure 29

The air shutter is adjusted by loosening the locking screw and rotating the shutter to allow more or less air into the tube. The centred position is usually about right. Tighten the screw, replace the assembly and check the flame pattern.

Oven Burner Assembly

The oven burner assembly is visible and accessible for servicing when the oven bottom panel is removed. The burner assembly is made up of several components as shown below.

thermocouple

burner

igniter

Oven burner assembly

Figure 30

IMPORTANT

The thermocouple and igniter positioning is very important to the operation of the oven. These two items must be checked before putting the appli- ance into operation. (see figure 31)

NOTE: Before putting the 7200 /9200 Gas Range into service, be

 

sure that all the setup procedures recommended in this manual

 

have been completed.

Figure 31

31

Page 31
Image 31
Heartland Bakeware 9200/7200 manual Air Shutter Adjustment oven burner only, Oven Burner Assembly