Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.

WARNING

EQUIPMENT MISUSE HAZARD

Misuse can cause death or serious injury.

Do not operate the unit when fatigued or under the influence of drugs or alcohol.

Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals.

Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer.

Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manu- facturer’s replacement parts only.

Do not alter or modify equipment.

Use equipment only for its intended purpose. Call your distributor for information.

Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces.

Do not kink or over bend hoses or use hoses to pull equipment.

Keep children and animals away from work area.

Comply with all applicable safety regulations.

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

• Use equipment only in well ventilated area.

• Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

• Keep work area free of debris, including solvent, rags and gasoline.

Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.

Ground all equipment in the work area. See Grounding instructions.

Use only grounded hoses.

Hold gun firmly to side of grounded pail when triggering into pail.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

4

311051F

Image 4
Contents Automatic XT Spray Guns Contents Related ManualsOrifice Size In. mm ModelsCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Selection Charts Hvlp Spray Gun AssembliesCompliant Spray Gun Assemblies Airspray Gun AssembliesGun Selection Proper Needle/Nozzle SelectionAir Caps Air Flow Hvlp Gun Air Cap PressureInstallation Ventilate Spray BoothConfigure Gun and Manifold Non-circulating SystemInstall Air Fittings Ground SystemMount Gun Reciprocating Arm Rod MountRetrofit Adapter Plate Stationary SupportConnect Air Line SetupConnect Fluid Hose Flush Spray Gun Position Air CapAdjust Spray Pattern Compliant Hvlp and Compliant Gun LimitsAir Pressure Regulator Pressure Relief Procedure OperationApply Fluid IncorrectDaily Gun Care Clean and Flush Gun General System MaintenancePerform Pressure Relief Procedure, General Troubleshooting TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Items Needed for Service ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Parts Exploded View Part No Gun ShownParts Air CapsPart No. Description Qty Orifice Size LargeSpray Gun Assemblies all models Needle TipsManifold with Bottom Fluid Ports Description Qty Manifold with Side Fluid PortsSide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Mounting Hole Layout Manifold Mounting Hole LayoutRear Port Manifold Retrofit Adapter Plate Gun with RetrofitTechnical Data Triggering SpeedGraco Standard Warranty Graco Information