Pressure Relief Procedure

1.Turn off all bleed type air valves and all other air and fluid supplies to the gun.

2.Trigger the gun into a grounded metal waste con- tainer to relieve air and fluid pressure.

TI8174a

FIG. 14: Pressure Relief

Apply Fluid

The spray gun has a built-in lead and lag operation. When triggered, the gun begins emitting air before the fluid is discharged. When the trigger actuation air is stopped, the fluid stops before the air flow stops. This helps ensure that the spray is atomized and prevents fluid buildup on the air cap and tip.

Adjust the system control device, if it is automatic, so the gun starts spraying just before meeting the part and stops as soon as the part has passed. Keep the gun a consistent distance, 6 to 8 in. (150 to 200 mm), from the surface of the object being sprayed.

Operation

To achieve best results when applying fluid:

Keep gun perpendicular and 6 to 8 in. (150 to 200 mm) from object being sprayed.

Use smooth, parallel strokes across surface to be sprayed with 50% overlap.

Incorrect

TI8098a

Correct

TI8099a

FIG. 15: Correct Spray Method

311051F

17

Image 17
Contents Automatic XT Spray Guns Related Manuals ContentsCompliant Airspray ModelsOrifice Size In. mm Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Hvlp Spray Gun Assemblies Selection ChartsAirspray Gun Assemblies Compliant Spray Gun AssembliesAir Caps Proper Needle/Nozzle SelectionGun Selection Hvlp Gun Air Cap Pressure Air FlowVentilate Spray Booth InstallationConfigure Gun and Manifold Non-circulating SystemGround System Install Air FittingsReciprocating Arm Rod Mount Mount GunRetrofit Adapter Plate Stationary SupportConnect Fluid Hose SetupConnect Air Line Position Air Cap Flush Spray GunCompliant Hvlp and Compliant Gun Limits Adjust Spray PatternAir Pressure Regulator Operation Pressure Relief ProcedureApply Fluid IncorrectDaily Gun Care Perform Pressure Relief Procedure, General System MaintenanceClean and Flush Gun Problem Cause Solution TroubleshootingGeneral Troubleshooting Troubleshooting Spray Pattern Troubleshooting Replace Fluid Packings and Air Seals ServiceItems Needed for Service Alternate Fluid Control Shown Reassembly Exploded View Part No Gun Shown PartsAir Caps PartsPart No. Description Qty Orifice Size LargeNeedle Tips Spray Gun Assemblies all modelsManifold with Bottom Fluid Ports Manifold with Side Fluid Ports Description QtySide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Manifold Mounting Hole Layout Mounting Hole LayoutRetrofit Adapter Plate Gun with Retrofit Rear Port ManifoldTriggering Speed Technical DataGraco Information Graco Standard Warranty