Graco 288217, 249369, 249377 important safety instructions Alternate Fluid Control Shown

Page 24

Service

13. Remove all o-rings from the piston (3) and stems

(T). Check that the stems are solidly in place. If they are loose, replace the entire piston assembly (3).

14. Perform the following applicable step:

a. Non-circulating guns: Remove the fluid outlet port plug (19), and gasket (22) from the fluid housing (2). Remove the o-ring (21) and backup (20) from the plug.

1 2

11* 3

2

2

10* 3

16 8

25

23 1 2

24

17 3

5

5a9

36

TI8199a

Alternate Fluid Control Shown

FIG. 21

b.Circulating guns: Remove the gasket (22) from the fluid housing (2).

15.Clean all parts and replace any worn parts. When assembling, lubricate the threads with anti-seize lubricant.

8*

3

4

2

4

T

 

 

 

6

 

 

 

 

7

29

30 6 7

93

33

12*

TI8103a

Cutaway View:

Part No. 249388 Gun Shown

SERVICE NOTES:

1Torque to 35-45 in-lb (4.0-5.1 N•m)

2Lubricate threads with anti-seize lubricant

3Lubricate with light-weight oil

4Tighten cap (4) until it bottoms out

6Apply semi-permanent anaerobic sealant

7Torque to 4-5 in-lb (0.45-0.57 N•m)

8Torque to 95-105 in-lb (10.7-11.8 N•m)

9Apply semi-permanent anaerobic sealant to two threads at end of needle shaft.

24

311051F

Image 24
Contents Automatic XT Spray Guns Contents Related ManualsModels Orifice Size In. mmCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Selection Charts Hvlp Spray Gun AssembliesCompliant Spray Gun Assemblies Airspray Gun AssembliesProper Needle/Nozzle Selection Gun SelectionAir Caps Air Flow Hvlp Gun Air Cap PressureInstallation Ventilate Spray BoothConfigure Gun and Manifold Non-circulating SystemInstall Air Fittings Ground SystemMount Gun Reciprocating Arm Rod MountRetrofit Adapter Plate Stationary SupportSetup Connect Air LineConnect Fluid Hose Flush Spray Gun Position Air CapAdjust Spray Pattern Compliant Hvlp and Compliant Gun LimitsAir Pressure Regulator Pressure Relief Procedure OperationApply Fluid IncorrectDaily Gun Care General System Maintenance Clean and Flush GunPerform Pressure Relief Procedure, Troubleshooting General TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Service Items Needed for ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Parts Exploded View Part No Gun ShownParts Air CapsPart No. Description Qty Orifice Size LargeSpray Gun Assemblies all models Needle TipsManifold with Bottom Fluid Ports Description Qty Manifold with Side Fluid PortsSide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Mounting Hole Layout Manifold Mounting Hole LayoutRear Port Manifold Retrofit Adapter Plate Gun with RetrofitTechnical Data Triggering SpeedGraco Standard Warranty Graco Information