Installation

Mount Gun

Reciprocating Arm Rod Mount

To mount the gun on a reciprocating arm rod [0.5 in. (13 mm) diameter maximum]:

1.Insert the mounting bar (A) through the hole in the manifold as shown in FIG. 5.

Use the 1/8 in. alignment pin (P) to assist in orient- ing the gun.

2.Secure the gun to the bar by tightening the mount- ing screw (B).

2.Secure the gun to the support with two M5 x 0.8 capscrews (C). The screws must be long enough to engage the threaded holes in the gun manifold to a depth of 1/4 in. (6 mm).

C

TI8095 a

B

P

A

TI8094a

FIG. 6: Stationary Support Mount

Retrofit Adapter Plate

The retrofit adapter plate enables the manifold to be attached to a variety of bolt patterns.

To mount the gun using the retrofit adapter plate (kit 288197):

1. Mount adapter plate to manifold using the three

FIG. 5: Reciprocating Arm Mount

Stationary Support

To mount the gun on a stationary support (refer to FIG. 6 and Mounting Hole Layout, page 35):

1.Align the manifold with the alignment pins. Locate alignment pins and holes per the Mounting Hole Layout illustration, page 35.

screws provided with the kit (FIG. 7).

2. Bolt plate to mounting surface using four M5 x 0.8

capscrews. Refer to the Mounting Hole Layout,

page 36.

TI8180a

FIG. 7: Retrofit Adapter Plate Mount

12

311051F

Image 12
Contents Automatic XT Spray Guns Contents Related ManualsModels Orifice Size In. mmCompliant Airspray Equipment Misuse Hazard Toxic Fluid or Fumes Hazard Selection Charts Hvlp Spray Gun AssembliesCompliant Spray Gun Assemblies Airspray Gun AssembliesProper Needle/Nozzle Selection Gun SelectionAir Caps Air Flow Hvlp Gun Air Cap PressureInstallation Ventilate Spray BoothConfigure Gun and Manifold Non-circulating SystemInstall Air Fittings Ground SystemMount Gun Reciprocating Arm Rod MountRetrofit Adapter Plate Stationary SupportSetup Connect Air LineConnect Fluid Hose Flush Spray Gun Position Air CapAdjust Spray Pattern Compliant Hvlp and Compliant Gun LimitsAir Pressure Regulator Pressure Relief Procedure OperationApply Fluid IncorrectDaily Gun Care General System Maintenance Clean and Flush GunPerform Pressure Relief Procedure, Troubleshooting General TroubleshootingProblem Cause Solution Troubleshooting Spray Pattern Troubleshooting Service Items Needed for ServiceReplace Fluid Packings and Air Seals Alternate Fluid Control Shown Reassembly Parts Exploded View Part No Gun ShownParts Air CapsPart No. Description Qty Orifice Size LargeSpray Gun Assemblies all models Needle TipsManifold with Bottom Fluid Ports Description Qty Manifold with Side Fluid PortsSide Fluid Ports and Fan Adjustment Valve RING, Ptfe Accessories Dimensions Mounting Hole Layout Manifold Mounting Hole LayoutRear Port Manifold Retrofit Adapter Plate Gun with RetrofitTechnical Data Triggering SpeedGraco Standard Warranty Graco Information