Graco 247937, 247936 Grounding, Fire, Explosion, and Electric Shock Hazard

Page 14

Installation

Grounding

Fire, Explosion, and Electric Shock Hazard

When operating the electrostatic gun, any ungrounded objects in the spray area (people, containers, tools, etc.) can become electrically charged. Improper grounding can result in static sparking, which can cause a fire, explosion, or electric shock. Follow the grounding instructions below.

All persons entering the spray area: shoes must have conductive soles, such as leather, or personal grounding straps must be worn. Do not wear shoes with non-conductive soles such as rubber or plastic. If gloves are necessary, wear the conductive gloves that are supplied with the gun. If non-Graco gloves are worn, cut off fingers or palm area of gloves to ensure your hand contacts the grounded gun han- dle.

The following are minimum grounding requirements for a basic electrostatic system. Your system may include other equipment or objects which must be grounded.

Check your local electrical code for detailed grounding instructions. Your system must be connected to a true earth ground.

Pump: ground the pump by connecting a ground wire and clamp as described in your separate pump instruction manual.

Object being sprayed: keep the workpiece hangers clean and grounded at all times. Resistance must not exceed 1 megohm.

The floor of the spray area: must be electrically con- ductive and grounded. Do not cover the floor with cardboard or any non-conductive material which would interrupt grounding continuity.

Electrostatic Air Spray Gun: ground the gun by con- necting the Graco Grounded Air Hose and connect- ing the air hose ground wire to a true earth ground. See Check Electrical Grounding, page 15.

ti1259a

Air compressors: ground the equipment according to the manufacturer's recommendations.

All air and fluid lines must be properly grounded. Use only grounded hoses with a maximum of 100 feet (30.5 m) combined hose length to ensure grounding continuity.

Flammable liquids in the spray area: must be kept in approved, grounded containers. Do not use plastic containers. Do not store more than the quantity needed for one shift.

All electrically conductive objects or devices in the spray area: including fluid containers and wash cans, must be properly grounded.

14

312900G

Image 14
Contents PRO Xs Waterborne Air Spray Gun II 2 G EEx 0.24 mJTable of Contents FIRE, EXPLOSION, and Electric Shock Hazard Equipment Misuse Hazard Smart Model 247937 OverviewHow the Electrostatic Air Spray Gun Works Standard Model 247936Air swivel inlet. Left-hand thread Fan air adjustment valve. Adjusts fan size ES indicator 247936 only. Green when ES is on Ventilate the Spray Booth InstallationInstall the System Typical Installation Key Grounded Air Supply Hose Connect the Air LineConnect the Charging Probe Filter the Fluid Connect the Exhaust TubeConnect the Fluid Line Select a Fluid Nozzle and Air Cap Orifice SizeGrounding Fire, Explosion, and Electric Shock HazardCheck Electrical Grounding Check Fluid ResistivityCheck Fluid Viscosity Prepare to PaintTurn ES ON/OFF switch on Flush Pressurized Equipment Hazard Pressure ReliefShutdown Maintenance Clean Gun DailyDaily System Care See Test Total Gun Resistance on Electrical TroubleshootingElectric Shock Hazard See Check Electrical Grounding onTest Total Gun Resistance Electrical TestsTest Gun Resistance Test Charging Probe ResistanceTest Power Supply Resistance Test Barrel ResistanceSpray Pattern Troubleshooting Gun Operation Troubleshooting Gun Repair Prepare the Gun for RepairReplace Air Cap/Nozzle Replace Fluid NeedleRemove Fluid Packing Remove Fluid PackingRepair Packing Rod Packing RodInstall Barrel Remove BarrelRemove and Replace Power Supply Power SupplyRepair Fan Air Adjustment Valve Remove and Replace Turbine AlternatorRepair Fluid Adjustment Valve Repair Air ValveRemove and Replace Atomizing Air Restrictor Valve Repair ES ON/OFF ValveRef. No Multi-tool PartsPart No 60 kV Electrostatic Gun, Series a Standard model Part No 60 kV Electrostatic Gun, Series a Smart model Ref. No ES ON/OFF Valve Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Smart Model controlsDescription Qty Description Qty Fluid Line Accessories AccessoriesAir Line Accessories Gun Accessories Miscellaneous AccessoriesTechnical Data Category DataGraco Warranty Graco Information