Graco 247937, 247936 important safety instructions Flush

Page 18

Installation

Flush

Fire, Explosion, and Electric Shock Hazard

Read Fire and Explosion, and Electric Shock Hazards, page 3. Follow steps 1-6below to flush the gun when using gun first time, changing colors, before fluid dries, at end of day, and before storing gun.

NOTICE

This gun has nylon components which will be dam- aged if you use methylene chloride as a flushing or cleaning solvent.

1. Turn ES ON/OFF switch OFF (O).

ti12724_x2

2. Relieve pressure, page 19.

ti1934

3.Change fluid source to solvent, or disconnect fluid line and connect solvent supply line to gun.

ti1287a

4.Point gun into grounded metal pail. Flush until clean solvent flows from gun.

ti1934

5. Relieve pressure, page 19.

ti1934

6. Hang gun from hook. Nozzle must point down.

ti12718

18

312900G

Image 18
Contents PRO Xs Waterborne Air Spray Gun II 2 G EEx 0.24 mJTable of Contents FIRE, EXPLOSION, and Electric Shock Hazard Equipment Misuse Hazard Smart Model 247937 OverviewHow the Electrostatic Air Spray Gun Works Standard Model 247936Air swivel inlet. Left-hand thread Fan air adjustment valve. Adjusts fan size ES indicator 247936 only. Green when ES is on Installation Install the SystemVentilate the Spray Booth Typical Installation Key Connect the Air Line Connect the Charging ProbeGrounded Air Supply Hose Connect the Exhaust Tube Connect the Fluid LineFilter the Fluid Select a Fluid Nozzle and Air Cap Orifice SizeGrounding Fire, Explosion, and Electric Shock HazardCheck Electrical Grounding Check Fluid ResistivityCheck Fluid Viscosity Prepare to PaintTurn ES ON/OFF switch on Flush Pressure Relief ShutdownPressurized Equipment Hazard Maintenance Clean Gun DailyDaily System Care See Test Total Gun Resistance on Electrical TroubleshootingElectric Shock Hazard See Check Electrical Grounding onTest Total Gun Resistance Electrical TestsTest Gun Resistance Test Charging Probe ResistanceTest Power Supply Resistance Test Barrel ResistanceSpray Pattern Troubleshooting Gun Operation Troubleshooting Gun Repair Prepare the Gun for RepairReplace Air Cap/Nozzle Replace Fluid NeedleRemove Fluid Packing Remove Fluid PackingRepair Packing Rod Packing RodInstall Barrel Remove BarrelRemove and Replace Power Supply Power SupplyRepair Fan Air Adjustment Valve Remove and Replace Turbine AlternatorRepair Fluid Adjustment Valve Repair Air ValveRemove and Replace Atomizing Air Restrictor Valve Repair ES ON/OFF ValveParts Part No 60 kV Electrostatic Gun, Series a Standard modelRef. No Multi-tool Part No 60 kV Electrostatic Gun, Series a Smart model Ref. No ES ON/OFF Valve Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Smart Model controlsDescription Qty Description Qty Accessories Air Line AccessoriesFluid Line Accessories Gun Accessories Miscellaneous AccessoriesTechnical Data Category DataGraco Warranty Graco Information