Graco 247936, 247937 Remove and Replace Atomizing Air Restrictor Valve, Repair ES ON/OFF Valve

Page 35

Remove and Replace Atomizing Air Restrictor Valve

1.Prepare the gun for repair, page 27.

2.Remove the atomizing air restrictor valve (23). Inspect the o-ring (23c*). Replace if necessary. See FIG. 22.

3.Install a new atomizing air restrictor valve (23), or disassemble and replace parts individually. The valve protrusion must be oriented to clear the air valve (21) shaft.

If the atomizing air restrictor valve is not desired, install the supplied plug (2).

4.Torque the valve housing (23a) to 15-20 in-lb (1.7-2.3 N•m).

23c* 2

23a

23d

23b

ti1508a

Fig. 22. Atomizing Air Restrictor Valve

Gun Repair

Repair ES ON/OFF Valve

1.Prepare the gun for repair, page 27.

2.Loosen the screw (48). Remove the valve.

3.Lubricate the o-rings (22a* and 22b*) with non-sili- cone grease, Part No. 111265. Do not over-lubri- cate.

NOTICE

Do not over-lubricate parts. Excessive lubricant on the o-rings can be pushed into the gun air passage and blemish the finish on the workpiece.

4.Clean and inspect parts for damage. Replace if nec- essary.

The protrusion on the retainer plate (22d) must point upward.

5.Reinstall the valve. Torque the screw (48) to 15-25 in-lb (1.7-2.8 N•m).

22g

22d

22e

22f

22b*

22c

22a*

ti12720

Fig. 23. ES ON/OFF Valve

312900G

35

Image 35
Contents II 2 G EEx 0.24 mJ PRO Xs Waterborne Air Spray GunTable of Contents FIRE, EXPLOSION, and Electric Shock Hazard Equipment Misuse Hazard Standard Model 247936 OverviewHow the Electrostatic Air Spray Gun Works Smart Model 247937Air swivel inlet. Left-hand thread Fan air adjustment valve. Adjusts fan size ES indicator 247936 only. Green when ES is on Ventilate the Spray Booth InstallationInstall the System Typical Installation Key Grounded Air Supply Hose Connect the Air LineConnect the Charging Probe Filter the Fluid Connect the Exhaust TubeConnect the Fluid Line Orifice Size Select a Fluid Nozzle and Air CapFire, Explosion, and Electric Shock Hazard GroundingCheck Fluid Resistivity Check Electrical GroundingPrepare to Paint Check Fluid ViscosityTurn ES ON/OFF switch on Flush Pressurized Equipment Hazard Pressure ReliefShutdown Clean Gun Daily MaintenanceDaily System Care See Check Electrical Grounding on Electrical TroubleshootingElectric Shock Hazard See Test Total Gun Resistance onTest Charging Probe Resistance Electrical TestsTest Gun Resistance Test Total Gun ResistanceTest Barrel Resistance Test Power Supply ResistanceSpray Pattern Troubleshooting Gun Operation Troubleshooting Prepare the Gun for Repair Gun RepairReplace Fluid Needle Replace Air Cap/NozzleRemove Fluid Packing Remove Fluid PackingPacking Rod Repair Packing RodRemove Barrel Install BarrelPower Supply Remove and Replace Power SupplyRemove and Replace Turbine Alternator Repair Fan Air Adjustment ValveRepair Air Valve Repair Fluid Adjustment ValveRepair ES ON/OFF Valve Remove and Replace Atomizing Air Restrictor ValveRef. No Multi-tool PartsPart No 60 kV Electrostatic Gun, Series a Standard model Part No 60 kV Electrostatic Gun, Series a Smart model Smart Model controls Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Ref. No ES ON/OFF ValveDescription Qty Description Qty Fluid Line Accessories AccessoriesAir Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataGraco Information Graco Warranty