Graco 247937, 247936 important safety instructions Repair Fluid Adjustment Valve, Repair Air Valve

Page 34

Gun Repair

Repair Fluid Adjustment Valve

1.Prepare the gun for repair, page 27.

2.Remove the fluid adjustment valve (25). It can only be replaced as a complete assembly. See FIG. 20..

3.Screw the valve (25) into the gun handle. Torque to 15-25 in-lb (1.7-2.8 N•m).

25

ti11931

Fig. 20. Fluid Adjustment Valve

Repair Air Valve

1.Prepare the gun for service, page 27.

2.Remove the barrel, page 31.

3.Remove the fluid adjustment valve (25) from the handle (17). Remove the spring (15). See FIG. 21.

NOTICE

Clean all parts in non-conductive solvent compati- ble with the fluid being used, such as xylol or min- eral spirits. Use of conductive solvents can cause the gun to malfunction.

4.Remove the air valve (21) with a pliers. Inspect the rubber sealing surface and replace the air valve if damaged.

NOTICE

When removing the air valve (21) be careful not to damage the seat area.The rubber seal is not removable.

5.Inspect the u-cup (6*). Do not remove the u-cup unless damaged. If removed, install the new one with its lips facing into the gun handle (17).

6.Install the air valve (21) and spring (15) into the gun handle (17).

7.Install the fluid adjustment valve (25). Torque to 15-25 in-lb (1.7-2.8 N•m).

8.Install the barrel, page 31.

25

21 15

17

*6

ti12717

Fig. 21. Air Valve

34

312900G

Image 34
Contents PRO Xs Waterborne Air Spray Gun II 2 G EEx 0.24 mJTable of Contents FIRE, EXPLOSION, and Electric Shock Hazard Equipment Misuse Hazard Smart Model 247937 OverviewHow the Electrostatic Air Spray Gun Works Standard Model 247936Air swivel inlet. Left-hand thread Fan air adjustment valve. Adjusts fan size ES indicator 247936 only. Green when ES is on Install the System InstallationVentilate the Spray Booth Typical Installation Key Connect the Charging Probe Connect the Air LineGrounded Air Supply Hose Connect the Fluid Line Connect the Exhaust TubeFilter the Fluid Select a Fluid Nozzle and Air Cap Orifice SizeGrounding Fire, Explosion, and Electric Shock HazardCheck Electrical Grounding Check Fluid ResistivityCheck Fluid Viscosity Prepare to PaintTurn ES ON/OFF switch on Flush Shutdown Pressure ReliefPressurized Equipment Hazard Maintenance Clean Gun DailyDaily System Care See Test Total Gun Resistance on Electrical TroubleshootingElectric Shock Hazard See Check Electrical Grounding onTest Total Gun Resistance Electrical TestsTest Gun Resistance Test Charging Probe ResistanceTest Power Supply Resistance Test Barrel ResistanceSpray Pattern Troubleshooting Gun Operation Troubleshooting Gun Repair Prepare the Gun for RepairReplace Air Cap/Nozzle Replace Fluid NeedleRemove Fluid Packing Remove Fluid PackingRepair Packing Rod Packing RodInstall Barrel Remove BarrelRemove and Replace Power Supply Power SupplyRepair Fan Air Adjustment Valve Remove and Replace Turbine AlternatorRepair Fluid Adjustment Valve Repair Air ValveRemove and Replace Atomizing Air Restrictor Valve Repair ES ON/OFF ValvePart No 60 kV Electrostatic Gun, Series a Standard model PartsRef. No Multi-tool Part No 60 kV Electrostatic Gun, Series a Smart model Ref. No ES ON/OFF Valve Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Smart Model controlsDescription Qty Description Qty Air Line Accessories AccessoriesFluid Line Accessories Gun Accessories Miscellaneous AccessoriesTechnical Data Category DataGraco Warranty Graco Information