Graco 247936, 247937 important safety instructions FIRE, EXPLOSION, and Electric Shock Hazard

Page 3

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

Electrostatic equipment must be used only by trained, qualified personnel who understand the require- ments of this manual.

Ground equipment, personnel, object being sprayed, and conductive objects in work area. See Grounding instructions.

Only use grounded Graco conductive air supply hoses.

Check gun and hose resistance and electrical grounding daily.

Use and clean equipment only in well ventilated area.

Interlock the gun air supply to prevent operation unless ventilating fans are on.

Use cleaning solvents with highest possible flash point when flushing or cleaning equipment. To com- ply with EN50050 requirements, cleaning solvents must have a flash point at least 5°C above ambient temperature.

Always turn the electrostatics off when flushing, cleaning or servicing equipment.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Keep work area free of debris, including solvent, rags and gasoline.

Keep a working fire extinguisher in the work area.

ELECTRIC SHOCK HAZARD

This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.

Turn off air supply before servicing equipment.

All electrical wiring must be done by a qualified electrician and comply with all local codes and regulations.

Do not touch gun electrode when electrostatics are on.

Do not expose to rain. Store indoors.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.

312900G

3

Image 3
Contents II 2 G EEx 0.24 mJ PRO Xs Waterborne Air Spray GunTable of Contents FIRE, EXPLOSION, and Electric Shock Hazard Equipment Misuse Hazard Standard Model 247936 OverviewHow the Electrostatic Air Spray Gun Works Smart Model 247937Air swivel inlet. Left-hand thread Fan air adjustment valve. Adjusts fan size ES indicator 247936 only. Green when ES is on Installation Install the SystemVentilate the Spray Booth Typical Installation Key Connect the Air Line Connect the Charging ProbeGrounded Air Supply Hose Connect the Exhaust Tube Connect the Fluid LineFilter the Fluid Orifice Size Select a Fluid Nozzle and Air CapFire, Explosion, and Electric Shock Hazard GroundingCheck Fluid Resistivity Check Electrical GroundingPrepare to Paint Check Fluid ViscosityTurn ES ON/OFF switch on Flush Pressure Relief ShutdownPressurized Equipment Hazard Clean Gun Daily MaintenanceDaily System Care See Check Electrical Grounding on Electrical TroubleshootingElectric Shock Hazard See Test Total Gun Resistance onTest Charging Probe Resistance Electrical TestsTest Gun Resistance Test Total Gun ResistanceTest Barrel Resistance Test Power Supply ResistanceSpray Pattern Troubleshooting Gun Operation Troubleshooting Prepare the Gun for Repair Gun RepairReplace Fluid Needle Replace Air Cap/NozzleRemove Fluid Packing Remove Fluid PackingPacking Rod Repair Packing RodRemove Barrel Install BarrelPower Supply Remove and Replace Power SupplyRemove and Replace Turbine Alternator Repair Fan Air Adjustment ValveRepair Air Valve Repair Fluid Adjustment ValveRepair ES ON/OFF Valve Remove and Replace Atomizing Air Restrictor ValveParts Part No 60 kV Electrostatic Gun, Series a Standard modelRef. No Multi-tool Part No 60 kV Electrostatic Gun, Series a Smart model Smart Model controls Ref. No Alternator Ref. No Fan Adjustment ValveRef. No Packing Rod Ref. No ES ON/OFF ValveDescription Qty Description Qty Accessories Air Line AccessoriesFluid Line Accessories Miscellaneous Accessories Gun AccessoriesCategory Data Technical DataGraco Information Graco Warranty