Troubleshooting

Convertible Electric Motor Runs -

No AC Output to Sprayer Control Board

Troubleshooting Procedure

(see following page for actual steps):

See step 1.

Is there over 10-20 AC volts?

YES

See the sprayer control board trou- bleshooting in this manual.

NO

See step 2.

Is there continuity?

YES

See step 3.

Is there continuity?

YES

See step 4.

Is there over 100

AC volts?

NO

NO

NO

Repair or replace the power cord.

Repair or replace the power cord.

Repair or replace wire splice(s) on the power cord wires.

YES

See step 5. Is there over 10-20 AC volts.

YES

Replace cord jack.

NO

Replace transformer.

12

3A0243A

Image 12
Contents Korean patent Related Manuals Operation 3A0242 Parts 3A0244 GunFire and Explosion Hazard Pressurized Aluminum Parts Hazard Maintenance Pressure Relief ProcedurePremium Sprayers Engine Oil Funnel Troubleshooting Problem Cause SolutionThroat packing nut just enough to stop leakage Troubleshooting Procedure Fluid Pump Runs ConstantlyControl Board Malfunction Control Board Malfunction Steps StepConvertible Electric Motor Will Not Run Convertible Electric Motor Will Not Run Steps StepSee step Is there over 10-20 AC volts? Beep Digital Display Messages Two blinks is the same as E=02Bearing Housing and Connecting Rod InstallationRemoval Relieve pressureDrive Housing Pinion Assembly/Clutch Armature/Clamp Pinion AssemblyClutch Armature Installation Clutch Housing Engine Pump ON/OFF Switch Pressure ControlPressure Adjust Potentiometer Control BoardPressure Control Transducer Displacement Pump Do Pressure Relief,Place u-bolt on pump door protrusion Tighten latch and rotate latch lock into locked posi- tion Hose Reel Grease shaft Install E-clip Pivot Replacement Technical Data Dimensions 3A0243A Graco Standard Warranty For Graco Canada Customers