SECTION 2: CIRCUIT REQUIREMENTS
110/220V Operation
Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.
Amperage Draw
The Model G1005Z features a 110/220V motor that is prewired for 110V and draws the following amps under maximum load:
Motor Draw at 110V | 12 | Amps |
Motor Draw at 220V | 6 | Amps |
Circuit Requirements
We recommend using a dedicated circuit for this machine. You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amper- age without consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.
110V Circuit | 15 Amps |
220V Circuit | 15 Amps |
G1005Z Mill/Drill
Plug Type
The Model G1005Z comes prewired with a NEMA
220V Plug & Receptacle | NEMA | |
|
|
|
|
|
|
|
|
|