Alpine 9000 Lack of Lubrication, Do not OVER-LUBRICATE, Over-Lubrication, Slow Speed Bearings

Page 24

Lack of Lubrication:

To avoid lack of lubrication, note the following:

1.As the lubricant film reduces, the sound level will increase. A rise of about 8 dB over baseline accompanied by a uniform rushing sound will indicate lack of lubrication.

2.When lubricating, add just enough to return the reading to base line.

3.Use caution. Some lubricants will need time to uniformly cover the bearing surfaces. Lubricate a small amount at a time.

DO NOT OVER-LUBRICATE

Over-Lubrication:

One of the most common causes of bearing failure is over-lubrication. The excess pressure of the lubricant often breaks, or “pops” bearing seals or causes a build-up of heat, which can create stress and deformity.

To avoid over-lubrication:

1.Don't lubricate if the base line reading and base line sound quality is maintained.

2.When lubricating, use just enough lubricant to bring the ultrasonic reading to baseline.

3.As mentioned above, use caution. Some lubricants will need time to uniformly cover the bearing surfaces.

Proper Lubrication

 

Lack of Lubrication

Reduces Friction

 

Increases Amplitude Levels

 

 

 

 

 

 

SLOW SPEED BEARINGS

Monitoring slow speed bearings is possible with the Ultraprobe 9000. Due to the sensitivity range and the frequency tuning, it is quite possible to listen to the acoustic quality of bearings. In extremely slow bearings (less 25 RPM), it is often necessary to disregard the display and listen to the sound of the bearing. In these extreme situations, the bearings are usually large (1/2" and up) and greased with high viscosity lubricant. Most often no sound will be heard as the grease will absorb most of the acoustic energy. If a sound is heard, usually a crackling sound, there is some indication of deformity occurring.

On most other slow speed bearings, it is possible to set a base line and monitor as described.

FFT INTERFACE

The Ultraprobe may be interfaced with FFT's via the UE-MP-BNC-2Miniphone to BNC connector or the UE DC2 FFT Adapter. The Miniphone plug is inserted into the headphone jack of the Ultraprobe and the BNC connector is attached to the analog-in connector of the FFT. There are also two accessories that connect to an FFT via the Ultraprobe I/O port. They are the 5PC MP (using a Miniphone connector to the FFT) and the 5PC-BNC(using a BNC connector to the FFT). These connectors enable an FFT to receive the heterodyned, (translated) low frequency sound information detected from the Ultraprobe. In this instance it can be used to monitor and trend bearings, including low speed bearings. It can also extend the use of the FFT to record all types mechanical information such as leaking valves, cavitation, gear wear, etc.

23

Image 24
Contents R a U N C U T a LRM-9 CFM-9 BPA-9BCH-WTG2 HTS-2 Sheath LLA 5PC-MP 5PC-BNC QCH-9 Page Operation Mode SET UP ModeOverview Basic ComponentsPISTOL-GRIP Housing Display Panel PLUG-IN ModulesTrisonictm Scanning Module Stethoscope Contact ModuleTrigger ON/OFF Trigger Switch Connector DiagramBattery Compartment BatteryAccessories WTG-2SP Warble Pipe Threaded Tone Generator BCH-WTG2Sheath LLAOperation Mode Sensitivity Control Dial To Adjust the SENSITIVITY/VOLUMEBAR Graph Display To Adjust the Frequency Yellow Store Button To Store a ReadingTo Overwrite Data or to Enter Data in a NEW Location Setup Mode Text EditorTo Enter Text in the Text Field Set Time and Date DB Offset Calibration Due Date Users Instructions TRISONIC- Scanning ModuleMethod of Airborne Detection Stethoscope ModuleAUTO-SHUTDOWN Battery Feature Resetting the on Board ComputerWarble Tone Generator UE-WTG-1 To Charge the Warble Tone GeneratorLeak Detection HOW to Locate Leaks To Confirm a LeakOvercoming Difficulties Shielding Techniques Tone Test UltratonePage Electric ARC, CORONA, Tracking Detection Monitoring Bearing Wear Procedure for Bearing History Historical Detecting Bearing FailureFor Comparative Test Lack of Lubrication Do not OVER-LUBRICATEOver-Lubrication Slow Speed BearingsGeneral Mechanical Trouble Shooting ProcedureLocating Faulty Steam Traps General STEAM/CONDENSATE/FLASH Steam ConfirmationPage Procedure for Valve Check Miscellaneous Problem Areas A. Underground Leaks Abcd MethodConfirming Valve Leakage in Noisy Pipe Systems Leakage Behind Walls Partial BlockageFlow Direction Page Instructions for Setting Combination on Carrying Case Hayes Street Elmsford, NY 10523 USA Tel