Alpine 9000 instruction manual Detecting Bearing Failure, For Comparative Test

Page 23

DETECTING BEARING FAILURE

There are two basic procedures of testing for bearing problems:

COMPARATIVE AND HISTORICAL. The comparative method involves testing two or more similar bearings and "comparing" potential differences. Historical testing requires monitoring a specific bearing over a period of time to establish its history. By analyzing bearing history, wear patterns at particular ultrasonic frequencies become obvious, which allows for early detection and correction of bearing problems.

FOR COMPARATIVE TEST

1.Use contact (stethoscope) module.

2.Select desired frequency. (If only one frequency is to be monitored, consider using 30 kHz.

3.Select a "test spot" on the bearing housing and mark it for future. Touch that spot with the contact module. In ultrasonic sensing, the more mediums or materials ultrasound has to travel through, the less accurate the reading will be. Therefore, be sure the contact probe is actually touching the bearing housing. If this is difficult, touch a grease fitting or touch as close to the bearing as possible.

4.Approach the bearings at the same angle, touching the same area on the bearing housing.

5.Reduce sensitivity to hear the sound quality more clearly.

6.Listen to bearing sound through headphones to hear the "quality" of the signal for proper interpretation.

7.Select same type bearings under similar load conditions and same rotational speed.

8.Compare differences of meter reading and sound quality.

PROCEDURE FOR BEARING HISTORY (HISTORICAL):

Before starting with the HISTORICAL method for monitoring bearings, the COMPARATIVE method must be used to determine a baseline.

1.Use basic procedure as outlined above in steps 1-8.

2.Save the reading for future reference.

3.Compare this reading with previous (or future readings). On all future readings, adjust frequency to the original level.

If the decibel level has moved up 12 dB over the base line, it indicates the bearing has entered the incipient failure mode.

Lack of lubrication is usually indicated by an 8 dB increase over baseline. It is usually heard as a loud rushing sound. If lack of lubrication is suspected, after lubricating, retest. If readings do not go back to original levels and remain high, consider bearing is on the way to the failure mode and recheck frequently.

22

Image 23
Contents R a U N C U T a BCH-WTG2 HTS-2 Sheath LLA 5PC-MP 5PC-BNC QCH-9 LRM-9 CFM-9BPA-9 Page Basic Components Operation ModeSET UP Mode OverviewStethoscope Contact Module PISTOL-GRIP Housing Display PanelPLUG-IN Modules Trisonictm Scanning ModuleBattery Trigger ON/OFF Trigger SwitchConnector Diagram Battery CompartmentAccessories LLA WTG-2SP Warble Pipe Threaded Tone GeneratorBCH-WTG2 SheathBAR Graph Display Operation ModeSensitivity Control Dial To Adjust the SENSITIVITY/VOLUME To Overwrite Data or to Enter Data in a NEW Location To Adjust the FrequencyYellow Store Button To Store a Reading To Enter Text in the Text Field Setup ModeText Editor Set Time and Date DB Offset Calibration Due Date Stethoscope Module Users InstructionsTRISONIC- Scanning Module Method of Airborne DetectionTo Charge the Warble Tone Generator AUTO-SHUTDOWN Battery FeatureResetting the on Board Computer Warble Tone Generator UE-WTG-1Leak Detection Overcoming Difficulties HOW to Locate LeaksTo Confirm a Leak Tone Test Ultratone Shielding TechniquesPage Electric ARC, CORONA, Tracking Detection Monitoring Bearing Wear For Comparative Test Procedure for Bearing History HistoricalDetecting Bearing Failure Slow Speed Bearings Lack of LubricationDo not OVER-LUBRICATE Over-LubricationProcedure General Mechanical Trouble ShootingGeneral STEAM/CONDENSATE/FLASH Steam Confirmation Locating Faulty Steam TrapsPage Procedure for Valve Check Confirming Valve Leakage in Noisy Pipe Systems Miscellaneous Problem Areas A. Underground LeaksAbcd Method Flow Direction Leakage Behind WallsPartial Blockage Page Instructions for Setting Combination on Carrying Case Hayes Street Elmsford, NY 10523 USA Tel