TEXT EDITOR:

TO ENTER TEXT IN THE TEXT FIELD:

If enabled (refer to SET UP MODE 07), Click the Store Button once after storing data

The text field will blink. If the field has no entry, it will display “UNKNOWN” and the first character will blink.

The Sensitivity control dial can be used to scroll through the alphabet, A-Z , a space character and then through numbers 0-9. Spin the Sensitivity dial clockwise to move up the alphabet and then to numbers or counter clockwise to move back through numbers (9-0) and then back down the alphabet (Z-A).

To enter, click the Sensitivity Control Dial to enter the text character.

The next location to the right will then blink. Continue until through or until all 8 fields are filled.

If an error in recording a letter or number occurs, click the Sensitivity Control Dial and the cursor will move to the right. Continue clicking the Sensitivity Control Dial and the cursor will “wrap” around to the right until the desired location is reached. As explained above, spin the Sensitivity Control Dial until the corrected entry is displayed and “click” the Sensitivity Control Dial to enter the text character.

When the text is correct, click the yellow Store Button to save and store the text. The instrument will return to the Operation Mode.

Location: 001

Text: [ UNKNOWN ]

Text Editor Display

5. SETUP MODE

To enter the Set Up Mode:

1. Make sure the Ultraprobe is off.

2. Press (click) both the Yellow Store button and the Sensitivity dial at the same time. Only after these two controls have been pressed, then squeeze the trigger. NOTE: Hold the Trigger in during any of the Set Up Mode operations.

3. When in the first Menu mode: Data Transfer, you may move to any of the other Menu modes by spinning the Sensitivity Control up or down (clockwise or counter clockwise).

4. When the desired Menu mode is reached, push (Click) the Sensitivity Control in.

5. You may spin to enter and exit any Menu mode in the Set Up mod as long as the trigger on/off switch is pressed

01 Data Transfer

NOTE: Before downloading data, be sure the Ultraprobe is connected to the computer.

To download data from the Ultraprobe to your computer:

1.Follow steps 1-3 in Set Up Mode

2.The first selection to be displayed on the screen will be Menu 01, Data Transfer.

3.Click the Sensitivity Control Dial and all the data will be transferred to the PC. (NOTE: For software management, refer to UltratrendTm Instructions.)

Menu 01

Select

Data Transfer

 

 

 

10

Image 11
Contents R a U N C U T a BCH-WTG2 HTS-2 Sheath LLA 5PC-MP 5PC-BNC QCH-9 LRM-9 CFM-9BPA-9 Page Basic Components Operation ModeSET UP Mode OverviewStethoscope Contact Module PISTOL-GRIP Housing Display PanelPLUG-IN Modules Trisonictm Scanning ModuleBattery Trigger ON/OFF Trigger SwitchConnector Diagram Battery CompartmentAccessories LLA WTG-2SP Warble Pipe Threaded Tone GeneratorBCH-WTG2 SheathBAR Graph Display Operation ModeSensitivity Control Dial To Adjust the SENSITIVITY/VOLUME To Overwrite Data or to Enter Data in a NEW Location To Adjust the FrequencyYellow Store Button To Store a Reading To Enter Text in the Text Field Setup ModeText Editor Set Time and Date DB Offset Calibration Due Date Stethoscope Module Users InstructionsTRISONIC- Scanning Module Method of Airborne DetectionTo Charge the Warble Tone Generator AUTO-SHUTDOWN Battery FeatureResetting the on Board Computer Warble Tone Generator UE-WTG-1Leak Detection Overcoming Difficulties HOW to Locate LeaksTo Confirm a Leak Tone Test Ultratone Shielding TechniquesPage Electric ARC, CORONA, Tracking Detection Monitoring Bearing Wear For Comparative Test Procedure for Bearing History HistoricalDetecting Bearing Failure Slow Speed Bearings Lack of LubricationDo not OVER-LUBRICATE Over-LubricationProcedure General Mechanical Trouble ShootingGeneral STEAM/CONDENSATE/FLASH Steam Confirmation Locating Faulty Steam TrapsPage Procedure for Valve Check Confirming Valve Leakage in Noisy Pipe Systems Miscellaneous Problem Areas A. Underground LeaksAbcd Method Flow Direction Leakage Behind WallsPartial Blockage Page Instructions for Setting Combination on Carrying Case Hayes Street Elmsford, NY 10523 USA Tel