Alpine 9000 instruction manual

Page 3

4.

Operation Mode

8

 

Display Panel

8

 

Bar Graph Display

8

 

Sensitivity Control Dial

8

 

 

∙ Sensitivity / Volume Adjust

8

 

 

Frequency Adjust

9

 

Yellow Store Button

9

 

 

Store a Reading

9

 

 

∙ Overwrite Data or Enter Data In a New Location

9

 

Text Editor

10

5.

Setup Mode

10

 

Data Transfer

10

 

∙ Set Time & Date

11

 

dB Scale Select

11

 

dB Offset Val(Value) (This is a Reference dB Level)

12

 

Display Mode

12

 

Calibration Due Date

13

 

Text Editor

13

 

Factory Defaults

13

 

Exit To Program

14

6.

User Instructions

14

 

Trisonic- Scanning Module

14

 

∙ Method of Airborne Detection

14

 

Headset

14

 

Rubber Focusing Probe

14

 

Stethoscope Module

14

 

Stethoscope Extension Kit

14

 

Charging The UP9000

14

 

Warble Tone Generator

15

 

∙ Charging The Warble Tone Generator

15

 

Helpful Hints

15

 

Auto Shutdown Battery Feature

15

 

∙ Resetting The On Board Computer

15

7.

Applications

 

 

Leak Detection, How to Locate Leaks, Shielding Techniques, Low Level Leaks

16-18

 

Tone Test (Ultratone)

18-19

 

Electric Arc, Corona, Tracking Detection

20-21

 

Monitoring Bearing Wear

21

 

Detecting Bearing Failure

22

 

Comparative & Historical Testing

22

 

Lack of Lubrication

23

 

Over Lubrication

23

 

Slow Speed Bearings

23

 

FFT Interface

23

 

General Mechanical Trouble Shooting

24

 

Locating Faulty Steam Traps

25

 

Traps: Inverted Bucket, Float & Thermostatic, Thermodynamic, Thermostatic

26

 

Inspecting Valves

27

 

ABCD Method

28

 

Leakage Behind Walls

29

 

Partial Blockage

29

 

Flow Direction

29

 

Ultrasound Technology

30

 

Instructions for Setting Combination Lock On Carrying Case

31

2

Image 3
Contents R a U N C U T a LRM-9 CFM-9 BPA-9BCH-WTG2 HTS-2 Sheath LLA 5PC-MP 5PC-BNC QCH-9 Page Basic Components Operation ModeSET UP Mode OverviewStethoscope Contact Module PISTOL-GRIP Housing Display PanelPLUG-IN Modules Trisonictm Scanning ModuleBattery Trigger ON/OFF Trigger SwitchConnector Diagram Battery CompartmentAccessories LLA WTG-2SP Warble Pipe Threaded Tone GeneratorBCH-WTG2 SheathOperation Mode Sensitivity Control Dial To Adjust the SENSITIVITY/VOLUMEBAR Graph Display To Adjust the Frequency Yellow Store Button To Store a ReadingTo Overwrite Data or to Enter Data in a NEW Location Setup Mode Text EditorTo Enter Text in the Text Field Set Time and Date DB Offset Calibration Due Date Stethoscope Module Users InstructionsTRISONIC- Scanning Module Method of Airborne DetectionTo Charge the Warble Tone Generator AUTO-SHUTDOWN Battery FeatureResetting the on Board Computer Warble Tone Generator UE-WTG-1Leak Detection HOW to Locate Leaks To Confirm a LeakOvercoming Difficulties Tone Test Ultratone Shielding TechniquesPage Electric ARC, CORONA, Tracking Detection Monitoring Bearing Wear Procedure for Bearing History Historical Detecting Bearing FailureFor Comparative Test Slow Speed Bearings Lack of LubricationDo not OVER-LUBRICATE Over-LubricationProcedure General Mechanical Trouble ShootingGeneral STEAM/CONDENSATE/FLASH Steam Confirmation Locating Faulty Steam TrapsPage Procedure for Valve Check Miscellaneous Problem Areas A. Underground Leaks Abcd MethodConfirming Valve Leakage in Noisy Pipe Systems Leakage Behind Walls Partial BlockageFlow Direction Page Instructions for Setting Combination on Carrying Case Hayes Street Elmsford, NY 10523 USA Tel