NAME

atmconfig - FORE/IP configuration tool

SYNOPSIS

atmconfig device

atmconfig -q peak off device

atmconfig -cvpi vci aal [ peak ] device

atmconfig -svpi vci aal [ peak ] device

DESCRIPTION

atmconfig is a tool to display and modify the current FORE/IP configuration. If no action is indicated for the specified device, the configuration information for the device is displayed. Configuration information includes the interface MTU, the peak rate used by SVCs, and the VC parameters for the FORE/IP connectionless and SPANS signaling VCs.

OPTIONS

-qSet/disable SVC rate shaping on the specified device. The peak rate is speci- fied in kilobits per second.

-cSet FORE/IP connectionless VC parameters for the given device. The con- nectionless VC will use VPI vpi, VCI vci, and AAL type aal. If peak is specified, traffic sent on the VC will be shaped to peak kilobits per second.

-sSet SPANS signaling VC parameters for the given device. The signaling VC will use VPI vpi, VCI vci, and AAL type aal. If peak is specified, traffic sent on the VC will be shaped to peak kilobits per second.

NOTES

The allowed values for vpi, vci, aal, and peak will depend on the capabilities of the ATM adapter used by the given interface. In addition, certain adapters may only support discrete peak cell rates. If so, the rate will be set to the closest sup- ported rate which is less than the specified rate.

The use of SVC rate control limits the peak bandwidth of all SVC traffic from the specified interface. If the peak rate is modified or disabled, the connections must be torn down (see na_atmarp [1]) and re-established for the new rate to take effect.

CLUSTER CONSIDERATIONS

In takeover mode, the FORE/IP SPANS interface names are those on the live filer, and in partner mode the interface names are those on the failed filer.

SEE ALSO

na_atmarp(1)

Dell PowerVault 7x0N Systems — Connecting to ATM and FDDI Networks

33

Image 37
Contents Page $%&$% Iii Duplex Fiber Optic Cable Connecting to an ATM Card Page Page #!% #!$!%$#!$ Page To start the configuration, perform the following steps $## Page #$#%$$$$$$&$ +,*--./ #$0$1$22$$2$%$1%$ #$0$1$22$$2$%$1%$2 Page 2424+4 Page +$## $$#!$$*!# %=%=*2DC,+ ######+ /etc/hosts file #$!%&$ Hostname +$ #0 #/* .+$Page FDDI-TP Two duplex Fddi Port B Fiber optic cables Port a Bypasspresent Return grounded internally Pin FunctionSynopsis Adconfig deviceCluster Considerations Adinfo -c device Input Cells Output CellsFraming Hdr-CRCCSProto CS-PDUsPay-CRC SARProtoOptions Atmarp -d hostname Atmarp -N hostname Atmarp -N -aAtmarp -f See Also Atmconfig device Atmconfig -q peak off device Delete ShowNaarp1 Add Wait Set -lecs