Fluke PN 643657 instruction sheet ∙Check, Disable and re-enable VCheck

Page 4

WVCheck

If a dc or ac voltage greater than about 4.5V is present across the inputs when the meter is set to R, G, or e, the meter switches automatically to dc or ac voltage mode (VCheck mode).

WWarning

Repetitive transients on a dc bus will cause VCheck to select ac volts, even though a hazardous dc voltage may be present. To avoid a misleading display and possible electric shock, manually select the proper volts function for measurements on these circuits.

When VCheck is activated, the meter has low input impedance (LoZ) 2 kΩ. This load can alter the voltages in electronic control circuits. Do not use VCheck to measure voltage in circuits that could be damaged by a 2 kΩ load.

Hint: VCheck can be effectively used to eliminate “ghost” voltages.

16 MULTIMETER

If AC detected

 

If DC detected

Meter puts 2 kΩ load on circuit.

OFF

V•Check

 

A

CAT

TEMPERATURE

600V

COM +

or

Disable and re-enable V•Check

For , and Ω , Disables V•Check and locks meter in selected mode.

2 sec

or

Re-enables

orV•Check

ip09i.eps

Image 4
Contents Multimeter with Temperature Read First Safety InformationSymbols Battery SaverAutomatic Range Selection Manual Range SelectionAC and DC Voltage Resistance and Continuity eRDisable and re-enable VCheck ∙CheckTemperature Capacitance E If the capacitor requires moreMicroamps μA Diode Test G Typical voltageMIN MAX μF Records the lowest and highest measurementsMIN MAX with Elapsed Time μF Disabling the Beeper Continuity CaptureMaintenance Replacement PartsSpecifications Function Range ResolutionMIN MAX Recording Accuracy and Response Time MIN MAX Recording with Elapsed Time Limited Warranty & Limitation of Liability