c)Connect the hose to the tank. Slide back the collar of the quick disconnect on the tank valve. Figure 7 (a). Push the male fitting of the regulator into the quick disconnect, and maintain pressure. Slide the collar closed. Figure 7 (b). If it does not engage or lock, repeat procedure. Gas will not flow unless the quick disconnect is properly engaged.

(a)

Male fitting

Regulator

Collar

(b)

Quick disconnect

Figure 7 engaged

d)Mix soap and water.

e)Open the tank valve. Figure 8.

E

F

Figure 8

f)Check for leaks by wetting the fitting with the soap and water solution and watching for bubbles. If bubbles form or if a bubble grows there is a leak.

If leak does not stop, turn off the gas and contact Weber-Stephen Customer Service. Do not use the barbecue.

g)When leak checks are complete, turn gas supply OFF and rinse connections with water.

LP Tank

The LP tank manufacturer is responsible for the materials, workmanship and performance of the tank. If the tank has a defect, malfunctions, or you have a question regarding the tank, call the tank manufacturer's customer service center. The phone number is on the warning decal which is permanently attached to the tank. If the tank manufacturer has not resolved the issue to your satisfaction, then call Weber-Stephen Products Co., Customer Service Center.

36

Image 36
Contents Genesis 5000 Series LP GAS Units only Warranty Patents and Trademarks Contents For Installation in Canada General InstructionsStorage Operating areaAssembly Check package contentsStep Page Page Check contents of hardware packs Assemble wheels Assemble frameContinue frame assembly Complete frame assemblyCheck the frame assembly Install left end panelInsert casters Install the three back panels Install side burner locksAdd cooking box Install side burner Install manifold bracketInstall tank panel assembly Install right end panelInstall bottom accessory trays Install igniterAdd fuel scale Install left hand swing table Check that all burner valves are offInstall right hand swing table Hinge rod View from rear of barbecue Set LP fuel scale Fill LP tankConnect LP tank Check for gas leaks Insert Flavorizer Bars Steam-N-Chips Smoker Install cooking grates Install the bottom trayInstall the lid Install glass doors Secure side burnerComplete accessory installation Lighting To ExtinguishManual Lighting Side burner will only operate when the Front burner is lit Lighting the side burnerPeriodic Cleaning CookingStorage and/or Nonuse Storage and/or NonuseUsing the Steam-N-Chips Smoker To use the Steam-N-Chips SmokerRefilling the LP tank Removal of the LP tankEngaged Safe handling tips for LP Gas Liquid Propane LP TanksAnnual Maintenance Inspection and Cleaning of the Weber Spider Stopper GuardsGeneral Maintenance Main Burner Cleaning ProcedureWeber Spider Stopper Guards Main Burner Flame PatternView from behind cooking box Wing nuts Crossover Ignition System Operations FlameCheck Safety System When burner is on HIGH. Flames do not run Burner does not light, or flame is low in High positionBurner flame pattern is erratic. Flame is low Resembles paint peelingSide Burner Troubleshooting Side Burner MaintenanceProblem Check Cure Side burner does not light Flame is low in High positionPage 19-20 22-24 Parts List Final Word Thanks
Related manuals
Manual 44 pages 20.87 Kb