Safe handling tips for LP Gas

Liquid Propane (LP) gas is a petroleum product as are gasoline and natural gas. LP gas is a gas at regular temperatures and pressures. Under moderate pressure, inside a tank, LP gas is a liquid. As the pressure is released the liquid readily vaporizes and becomes gas.

LP gas has an odor similar to natural gas. You should know this odor.

LP gas is heavier than air. Leaking LP gas may collect in low areas that prevent dispersion.

To fill, take the LP tank to an RV center, or look up gas-propane in the phone book for other sources of LP gas, to fill the tank with 20 pounds of liquid propane.

WARNING: We recommend that your LP tank be filled at an authorized LP gas dealer, by a qualified attendant, who fills the tank by weight. IMPROPER FILLING IS DANGEROUS.

CAUTION: If you exchange your LP tank, make sure you get a similar tank in return. Your LP tank is equipped with a quick-disconnect valve. Other LP tanks are not compatible with your barbecue connection.

Air must be removed from a new LP tank before the initial filling. Your LP dealer is equipped to do this.

The LP tank must be installed, transported and stored in an upright position. LP tanks should not be dropped or handled roughly.

Never store or transport the LP tank where temperatures can reach 125° F (too hot to hold by hand - for example: do not leave the LP tank in a car on a hot day).

Note - A refill will last about 20 hours of cooking time at normal use. The fuel scale will indicate the propane supply so you can refill before running out. You do not have to run out before you refill.

Treat "empty" LP tanks with the same care as when full. Even when the LP tank is empty of liquid there still may be gas pressure in the tank. Always close the tank valve before disconnecting.

Do not use a damaged LP tank. Dented or rusty LP tanks or LP tanks with a damaged valve may be hazardous and should be replaced with a new one immediately. See "LP tank requirements".

The joint where the hose connects to the LP tank must be leak tested each time the LP tank is reconnected. For example, test each time the LP tank is refilled.

Be sure the regulator is mounted with the small vent hole pointed downward so it will not collect water. This vent should be free of dirt, grease, bugs etc.

Liquid Propane (LP) Tank(s)

The LP tank and connections supplied with your Weber Gas Barbecue have been designed and tested to meet government, American Gas Association and Underwriters Laboratories requirements.

Replacement LP tanks supplied by Weber satisfy the requirements. Check to be sure the tank has a D.O.T. certification, and has been tested within five years. Your LP gas supplier can do this for you. Figure 9.

If you have questions about spare LP tanks, please call Weber-Stephen Customer Service.

D.O.T. Certification (example)

DOT 4BA240

2/96

20 lb LP tank

Date Tested

Figure 9

All LP tank supply systems must include a collar to protect the tank valve.

The LP tank must be a 20 lb size (18 1/4 inches high, 12 1/4 inches in diameter).

The LP tank must be constructed and marked in accordance with the specifications for LP gas cylinders of the U.S. Department of Transportation (D.O.T.).

37

Image 37
Contents Genesis 5000 Series LP GAS Units only Warranty Patents and Trademarks Contents General Instructions For Installation in CanadaStorage Operating areaCheck package contents AssemblyStep Page Page Check contents of hardware packs Assemble frame Assemble wheelsComplete frame assembly Continue frame assemblyInstall left end panel Check the frame assemblyInsert casters Install side burner locks Install the three back panelsAdd cooking box Install manifold bracket Install side burnerInstall right end panel Install tank panel assemblyInstall igniter Install bottom accessory traysAdd fuel scale Check that all burner valves are off Install left hand swing tableInstall right hand swing table Hinge rod View from rear of barbecue Fill LP tank Set LP fuel scaleConnect LP tank Check for gas leaks Insert Flavorizer Bars Steam-N-Chips Smoker Install the bottom tray Install cooking gratesInstall the lid Secure side burner Install glass doorsComplete accessory installation To Extinguish LightingManual Lighting Lighting the side burner Side burner will only operate when the Front burner is litCooking Periodic CleaningStorage and/or Nonuse Storage and/or NonuseTo use the Steam-N-Chips Smoker Using the Steam-N-Chips SmokerRemoval of the LP tank Refilling the LP tankEngaged Liquid Propane LP Tanks Safe handling tips for LP GasInspection and Cleaning of the Weber Spider Stopper Guards Annual MaintenanceMain Burner Cleaning Procedure General MaintenanceWeber Spider Stopper Guards Main Burner Flame PatternView from behind cooking box Wing nuts Crossover Ignition System Operations FlameCheck Safety System Burner does not light, or flame is low in High position When burner is on HIGH. Flames do not runBurner flame pattern is erratic. Flame is low Resembles paint peelingSide Burner Maintenance Side Burner TroubleshootingProblem Check Cure Side burner does not light Flame is low in High positionPage 19-20 22-24 Parts List Final Word Thanks