Bostitch BTFP12182 manual Safety Instructions, AIR Supply and Connections, Loading Tool, Operation

Page 3

SAFETY INSTRUCTIONS

EYE PROTECTION which conforms to ANSI specifications and provides protection against flying particles both from the FRONT and SIDE should ALWAYS be worn by the operator and others in the work area when connecting to air supply, loading, operating or servicing this tool. Eye protection is required to guard against flying fasteners and debris, which could cause severe eye injury.

The employer and/or user must ensure that proper eye protection is worn. Eye protection equipment must conform to the requirements of the American National Standards Institute, ANSI Z87.1 and provide both frontal and side protection. NOTE: Non-side shielded spectacles and face shields alone do not provide adequate protection.

CAUTION: Additional Safety Protection will be required in some environments. For example, the working area may include exposure to noise level which can lead to hearing damage. The employer and user must ensure that any necessary hearing protection is provided and used by the operator and others in the work area. Some environments will require the use of head protection equipment. When required, the employer and user must ensure that head protection conforming to ANSI Z89.1 is used.

AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury.

Do not use supply sources which can potentially exceed 200 P.S.I.G. as tool may burst, possibly causing injury.

The connector on the tool must not hold pressure when air supply is disconnected. If a wrong fitting is used, the tool can remain charged with air after disconnecting and thus will be able to drive a fastener even after the air line is disconnected possibly causing injury.

Do not pull trigger while connected to the air supply as the tool may cycle, possibly causing injury.

Always disconnect air supply: 1.) Before making adjustments; 2.) When servicing the tool; 3.) When clearing a jam; 4.) When tool is not in use; 5.) When moving to a different work area, as accidental actuation may occur, possibly causing injury.

LOADING TOOL

When loading tool: 1.) Never place a hand or any part of body in fastener discharge area of tool; 2.) Never point tool at anyone; 3.) Do not pull the trigger as accidental actuation may occur, possibly causing injury.

OPERATION

Always handle the tool with care: 1.) Never engage in horseplay; 2.) Never pull the trigger unless nose is directed toward the work; 3.) Keep others a safe distance from the tool while tool is in operation as accidental actuation may occur, possibly causing injury.

Keep hands and body away from the discharge area of the tool.

Do not drive fasteners on top of other fasteners or with the tool at an overly steep angle as this may cause deflection of fasteners which could cause injury.

This stapler produces SPARKS during operation. NEVER use the stapler near flammable substances, gases or vapors including lacquer, paint, benzine, thinner, gasoline, adhesives, mastics, glues or any other material that is -- or the vapors, fumes or by-products of which are -- flammable, combustible or explosive. Using the stapler in any such environment could cause an EXPLOSION resulting in personal injury or death to user and bystanders.

MAINTAINING THE TOOL

When working on tools note the warnings in this manual and use extra care when evaluating problem tools.

BTFP12182 TOOL SPECIFICATIONS

MODEL

LENGTH

HEIGHT

WIDTH

WEIGHT

 

 

 

 

 

BTFP12182

14.2" (360mm)

13.2” (335mm)

6.9” (174mm)

13.2lbs (6kg)

 

 

 

 

 

-3-

Image 3
Contents BTFP12182 Limited Warranty IntroductionIndex Loading Tool Safety InstructionsBTFP12182 Tool Specifications AIR Supply and ConnectionsAIR Consumption Fastener SpecificationsTool AIR Fitting Operating PressureLoading LubricationLoading the BTFP12182 Cold Weather OperationTrigger Operated Tool BTFP12182 AdjustmentsStaple Length Adjustments Tool Operation CheckMaintaining the Pneumatic Tool Replacement PartsAssembly Procedure for Seals AIR SUPPLY-PRESSURE and VolumeProblem Cause Correction Trouble ShootingGarantía Limitada IntroducciónÍndice NotaFuncionamiento Instrucciones DE SeguridadSuministro DE Aire Y Conexiones Carga DE LA HerramientaOperación CON Gatillo Conector DE Aire DE LA HerramientaPresión Operativa Consumo DE AireFuncionamiento EN Clima Frío LubricaciónCarga DE LA Unidad BTFP12182 FiltroAjustes DE Longitud DE LAS Grapas Ajustes DE BTFP12182Carga Liberación DE AtascamientosMantenimiento DE LA Herramienta Neumática Revisión Funcional DE LA HerramientaProblema Causa Corrección Solución DE ProblemasGarantie Limitée RemarqueFonctionnement Consignes DE SécuritéAlimentation Dair ET Connexions Chargement DE L’OUTILCaractéristiques Techniques DE L’OUTIL BTFP12182 Fonctionnement PAR Temps Froids LubrificationChargement DE LA BTFP12182 FiltreRéglages DE LA Longueur Dagrafe Réglages Pour BTFP12182Chargement DéblocageEntretien DE L’OUTIL Pneumatique Vérification DU Fonctionnement DE L’OUTILDépannage Problème Cause Solution