Bostitch BTFP12182 Fastener Specifications, Tool AIR Fitting, Operating Pressure, AIR Consumption

Page 4

FASTENER SPECIFICATIONS:

MODEL

STAPLE SERIES

WIRE SIZE

CROWN WIDTH

FASTENER RANGE

 

 

 

 

 

BTFP12182

SW9060

06” x .09”

1-1/4”

1-1/2”

(1.52mm x 2.25mm)

(32mm)

(38mm)

 

 

 

 

 

 

 

TOOL AIR FITTING:

This tool must use a male free-flow connector plug, 1/4” N.P.T. The minimum inside diameter should be .200” (5mm). The fitting must be capable of discharging tool air pressure when disconnected from the air supply.

OPERATING PRESSURE:

The operating pressure of the tool is 70 to 100 p.s.i. (5 to 7 kg/cm2). Select the operating pressure within this range for best fastener performance. DO NOT EXCEED THIS RECOMMENDED OPERATING PRESSURE.

AIR CONSUMPTION:

Model BTFP12182 requires 22.7 cubic feet per minute (.64 cubic meters) of free air to operate at the rate of 100 fasteners per minute, at 80 p.s.i. (5.66kg/cm2). Take the actual rate at which the tool will be run to determine the amount of air required. For instance, if your fastener usage averages 50 fasteners per minute, you need 50% of the tool's c.f.m. of free air which is required for running at 100 fasteners per minute.

OPERATION

BOSTITCH OFFERS ONE TYPE OF OPERATION FOR THIS SERIES TOOL.

TRIGGER OPERATED

This is a trigger operated model cycled by actuation of the trigger. The trigger operated tool will cycle every time the trigger is actuated.

AIR SUPPLY AND CONNECTIONS

Do not use oxygen, combustible gases, or bottled gases as a power source for this tool as tool may explode, possibly causing injury.

FITTINGS:

Install a male plug on the tool which is free flowing and which will release air pressure from the tool when disconnected from the supply source.

HOSES:

Air hoses should have a minimum of 150 p.s.i. (10.6 kg/cm2) working pressure rating or 150 percent of the maximum pressure that could be produced in the air system. The supply hose should contain a fitting that will provide “quick disconnecting” from the male plug on the tool.

SUPPLY SOURCE:

Use only clean regulated compressed air as a power source for this tool. NEVER USE OXYGEN, COMBUSTIBLE GASES, OR BOTTLED GASES, AS A POWER SOURCE FOR THIS TOOL AS TOOL MAY EXPLODE.

REGULATOR:

A pressure regulator with an operating pressure of 0 - 125 p.s.i. (0 - 8.79 kg/cm2) is required to control the operating pressure for safe operation of this tool. Do not connect this tool to air pressure which can potentially exceed 200 p.s.i. (14 kg/cm2) as tool may fracture or burst, possibly causing injury.

OPERATING PRESSURE:

Do not exceed recommended maximum operating pressure as tool wear will be greatly increased. The air supply must be capable of maintaining the operating pressure at the tool. Pressure drops in the air supply can reduce the tool’s driving power. Refer to “TOOL SPECIFICATIONS” for setting the correct operating pressure for the tool.

FILTER:

Dirt and water in the air supply are major causes of wear in pneumatic tools. A filter will help to get the best performance and minimum wear from the tool. The filter must have adequate flow capacity for the specific installation. The filter has to be kept clean to be effective in providing clean compressed air to the tool. Consult the manufacturer’s instructions on proper maintenance of your filter. A dirty and clogged filter will cause a pressure drop which will reduce the tool’s performance.

-4-

Image 4
Contents BTFP12182 Introduction Limited WarrantyIndex Safety Instructions BTFP12182 Tool SpecificationsAIR Supply and Connections Loading ToolFastener Specifications Tool AIR FittingOperating Pressure AIR ConsumptionLubrication Loading the BTFP12182Cold Weather Operation LoadingBTFP12182 Adjustments Staple Length AdjustmentsTool Operation Check Trigger Operated ToolReplacement Parts Assembly Procedure for SealsAIR SUPPLY-PRESSURE and Volume Maintaining the Pneumatic ToolTrouble Shooting Problem Cause CorrectionIntroducción ÍndiceNota Garantía LimitadaInstrucciones DE Seguridad Suministro DE Aire Y ConexionesCarga DE LA Herramienta FuncionamientoConector DE Aire DE LA Herramienta Presión OperativaConsumo DE Aire Operación CON GatilloLubricación Carga DE LA Unidad BTFP12182Filtro Funcionamiento EN Clima FríoAjustes DE BTFP12182 CargaLiberación DE Atascamientos Ajustes DE Longitud DE LAS GrapasRevisión Funcional DE LA Herramienta Mantenimiento DE LA Herramienta NeumáticaSolución DE Problemas Problema Causa CorrecciónRemarque Garantie LimitéeConsignes DE Sécurité Alimentation Dair ET ConnexionsChargement DE L’OUTIL FonctionnementCaractéristiques Techniques DE L’OUTIL BTFP12182 Lubrification Chargement DE LA BTFP12182Filtre Fonctionnement PAR Temps FroidsRéglages Pour BTFP12182 ChargementDéblocage Réglages DE LA Longueur DagrafeVérification DU Fonctionnement DE L’OUTIL Entretien DE L’OUTIL PneumatiqueProblème Cause Solution Dépannage