Specifications
Electrical Specifications of XS400
Output power at 12 VDC input |
|
| ||||
• Continuous | 400 VA1, 32 °F to 104 °F | |||||
|
|
|
|
| (0 °C to 40 °C), derated | |
|
|
|
|
| linearly to 300 VA at | |
|
|
|
|
| 122 °F (50 °C) | |
• Surge capacity for 5 seconds | 800 VA | |||||
|
|
|
|
|
| |
Input voltage | 12 VDC nominal | |||||
|
|
|
|
| 10.3 to 15.3 VDC | |
|
|
|
|
|
| |
Output voltage | 120 VAC RMS ± 3 VAC | |||||
|
|
|
|
|
| |
Output frequency | 60 Hz ± 0.05 Hz | |||||
|
|
|
|
|
| |
Output wave form | Sine wave | |||||
|
|
|
|
|
|
|
Total harmonic distortion of output waveform | <3% |
| ||||
|
|
|
|
|
|
|
High battery shutdown | 15.3 | ± 0.3 VDC | ||||
|
|
|
|
|
|
|
Low battery indication | 10.7 | ± 0.3 VDC | ||||
|
|
|
|
|
|
|
Low battery shutdown | 10.3 | ± 0.3 VDC | ||||
|
|
|
|
|
|
|
Maximum efficiency | 88% |
| ||||
|
|
|
|
|
|
|
No load current draw with switch turned to On ( |
| ) |
|
| 1.25 | ADC maximum |
| ||||||
| ||||||
|
|
|
|
|
| |
No load current draw with switch set to Standby ( |
| ) | 0 ADC | |||
| ||||||
| ||||||
|
|
|
|
|
| |
Supplemental circuit protector | 7.5 AAC | |||||
|
|
|
|
|
|
|
1.The term “watts” has been used throughout the guide to refer to output power. More correctly, the actual unit of power used is “VA”.
Physical Specifications of XS400 with Projections
Length
Width
Height
Weight
13.5inches (343 mm)
7.36inches (187 mm)
3.27inches (83 mm) 10 lb (4.54 kg)