Installation

3.Locate the wiring box access panel, and remove the three screws to access the wiring box as shown in Figure 2-7.

Figure 2-7Removing the 3 Screws on the Wiring Box Access Panel

4.Remove the wiring box access panel from the unit.

5.Install a 1/2 inch cable clamp.

6.Locate the terminal block.

The three terminals are labelled as follows:

L Line

N Neutral

Ground

7.Strip about 2 inches (50 mm) off the jacket of the AC output cable.

The AC output cable must be either solid or stranded, within the range of No. 14 to No. 18 AWG, and have three conductors.

8.Strip approximately 3/8 inch (10 mm) off the insulation of the cable.

9.Run the AC cable through the cable clamp and into the wiring box.

10.Using the 1/8 inch slot screwdriver, loosen the wire attachment screws on the terminals by five turns.

11.Insert and fasten the Ground wire into the corresponding terminal.

12.Insert the Line and Neutral wires into the corresponding terminals.

2–20

975-0054-01-01

Page 42
Image 42
Xantrex Technology XS400 manual 7Removing the 3 Screws on the Wiring Box Access Panel