Resetting After a Fault or Shutdown

Resetting After a Fault or Shutdown

This section provides explanations and procedures for resetting the XS400 after a fault or shutdown.

If you are unable to resolve the problem after referring to Table 3-3, refer to the “Troubleshooting” section on page 4–2.

Table 3-3Resetting After A Fault or Shutdown

Fault

Status

Action

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shutdown

The XS400 needs to be reset.

Turn the On/Standby switch on either the

 

 

inverter’s front panel or the S400 Remote

 

 

Switch to Standby (

 

 

 

 

 

 

) and then to On (

 

).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Short circuit

If there is a short circuit, the

Remove the short circuit then press the

 

Supplemental Circuit Protection

Supplemental Circuit Protection button.

 

button trips.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ground Fault

When a fault condition is

Reset: To resume normal operation,

 

detected, the Reset button on the

determine and correct the ground fault,

 

GFCI outlet trips and power to the

then press the Reset button.

 

appliances is interrupted.

Test: Press the Test button on the GFCI

 

 

outlet with either shore power and/or the

 

 

XS400 turned to On (

 

 

 

). The Reset button

 

 

 

 

 

 

 

 

 

 

 

 

should trip. Press the Reset button to reset

 

 

the GFCI and to continue with normal

 

 

operation. This test should be performed

 

 

on a monthly basis.

 

 

If the Reset button does not trip, the GFCI

 

 

may have failed. Contact your dealer to

 

 

have a qualified service person examine

 

 

the XS400.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overload

The XS400 is designed to provide

Disconnect the appliances connected to

 

400 watts continuously and 800

the inverter and then turn the On/Standby

 

watts surge capability for five

switch on either the inverter’s front panel

 

seconds. If the connected

or the S400 Remote Switch to Standby

 

appliances draw more than the

(

 

) and then to On (

 

).

 

 

 

 

 

 

rated power, the XS400 will shut

 

 

 

 

 

 

 

 

 

 

 

 

 

down and the red Fault light

See also “Recharging Your Batteries

 

illuminates.

When Low Battery Light Illuminates” on

 

 

page 3–6.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

975-0054-01-01

3–9

Page 59
Image 59