Installation

Close to

Long DC cables must be very large (and expensive), so

battery

they should be kept short (see Table 2-1 on page 2–9).

compartment

However, the unit should NOT be installed in the battery

 

compartment due to the possible presence of explosive

 

hydrogen gas from the batteries.

Protected

Never allow battery acid to drip on the inverter or its

from battery

wiring when filling the batteries or reading their specific

acid and

gravity. Do not mount the unit where it will be exposed to

gases

gases produced by the batteries. These gases are corrosive

 

and prolonged exposure will damage the inverter.

Orientation

To meet regulatory requirements, the XS400 must be

 

mounted on a flat horizontal surface with the front panel in

 

the upright position.

Battery Requirements

CAUTION

The XS400 Sine Wave Inverter must only be connected to batteries with a nominal output voltage of 12 volts. The XS400 Sine Wave Inverter will not operate from a 6 volt battery and will be damaged if connected to a 24 volt battery.

The batteries that you use strongly affect the performance of the XS400. It is important to connect the inverter to the correct size and type of battery.

See Appendix B, “Battery Types and Sizes” on page B–1for more information.