TESTING

Turn on the circuit breaker and light switch.

Note: Sensor has a 1 1/2 minute warm up pe- riod before it will detect motion.When first turned on wait 1 1/2 minutes.

Note: Meets the ENERGY STAR® guidelines when DualBrite® function is off.

Switch the on-time to TEST position and DualBrite® switch to the OFF position.

TEST 1 5 10 MIN

OFF 3 6 DUSK TO

ON-TIME

HOUR DAWN

Avoid aiming the control at:

Pools of water or objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearbylarge,light-coloredobjectsreflect- ing daylight may trigger the shut-off feature. Do not point other lights at the sensor.

150°

6 ft.

(1.8 m)

30ft.

(9.1m)

Maximum Range

Maximum

 

Coverage Angle

The detector is less sensitive to motion di- rectly towards it and more sensitive to across motion.

MotionMotion

Sensor

Least Sensitive

Most Sensitive

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head left or right to change the coverage area.

Note: Grasp the sensor only as shown and turn the entire sensor. Any other method may damage the sensor. Do not force it past the stops.

240°

Sensor Aiming

 

 

Adjustment Angle

If you need to change the sensitivity, temporarily remove the fixture and make the adjustment.Too much sensitivity may increase false triggering.

Set the amount of TIME you want the light to stay on after motion is detected. (1, 5, or 10 minutes).

Set the amount of time after dusk you want the lights on accent level.

595-5578-09

Image 6
Contents Operation FeaturesSome codes require installation by a qualified electrician RequirementsInstallation Mode Switching SummaryDualBrite Dimmer Control Wiring As Shipped Rotated Optional Wiring Wiring Diagram Master SlaveWiring Diagram Complete the Installation Top AssemblyOptional Assembly Testing Turn on the circuit breaker and light switchAvoid aiming the control at Specifications Troubleshooting GuideTechnical Service No Service Parts Available for this ProductFuncionamiento CaracterísticasRequisitos Instalacion Luz de Adorno DualBriteADVERTENCIADesconecte la ener- gía en el disyuntor Cableado Como se enviaronGirada Diagrama de Cableado Conexion AlternaMaestra Esclava Montaje Opcional Complete LA InstalacionEnsamble superior del Modelo Calafatee el aparato y la superficie dePrueba Prenda el cortacircuitos y el interruptor de luzEvite apuntar el control hacia Especificaciones Guia DE Investigacion DE AveriasServicio Técnico No hay piezas de servicio disponibles para este productoFonctionnement ExigencesCaractéristiques Résumé du mode de commutation Minuterie DualBriteMDTel qu’expédié Méthode de mise à la terre recommandéeCâblage Après rotationDiagramme de câblage Câblage FacultatifStandardMaître Satellite Complétez Linstallation Ensemble supérieurEnsemble facultatif Essais Portée maximale Angle de Couverture maximaleFiche Technique Guide DE DépannageService Technique Aucune pièce de rechange n’est disponible pour ce produit