SPECIFICATIONS
Range | Up to 30 ft. (9.1 m) |
| [varieswithsurrounding |
| temperature] |
Sensing Angle. . . | Up to 150° |
Electrical Load. . . | See rating on fixture |
| for maximum wattage |
Sensor Capacity . . | Upto360Watts(3.0A.) |
| Maximum Tungsten |
| Incandescent |
Power Requirements 120 VAC, 60 Hz | |
Operating Modes. . | TEST, AUTO, and |
| MANUAL MODE |
Time Delay . . . . | 1, 5, 10 minutes |
DualBrite® Timer. . | Off, 3, 6 hours, |
| dawn |
HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.
TROUBLESHOOTING GUIDE
SYMPTOM | POSSIBLE CAUSE | |
|
|
|
Light will not | 1. | Light switch is turned off. |
come on. | 2. Bulb is loose or burned out. | |
| 3. | Fuse is blown or circuit breaker |
|
| is turned off. |
| 4. | Daylight |
|
| (recheck after dark). |
| 5. | Incorrect circuit wiring, if this |
|
| is a new installation. |
| 6. | |
|
| desired area. |
|
| |
Light comes on | 1. Light control may be installed | |
in daylight. |
| in a relatively dark location. |
| 2. | Light control is in Test. (Set |
|
| control switch to an |
|
| position.) |
|
| |
Light comes on | 1. Light control may be sensing | |
for no apparent |
| small animals or automobile |
reason. |
| traffic |
| 2. | Sensitivity is set too high. |
|
| (Reduce sensitivity.) |
|
|
|
SYMPTOM | POSSIBLE CAUSE | |
|
| |
Light stays on | 1. The sensor is pointed toward | |
continuously. |
| a heat source like an air vent, |
|
| dryer vent, or |
|
| |
|
| sensor.) |
| 2. | Light control is in Manual Mode. |
|
| (Switch to Auto.) |
| 3. | Light control is in DualBrite® |
|
| mode. |
| 4. | Sensitivity is set too high. (Re- |
|
| duce sensitivity.) |
|
| |
Light flashes | 1. Heat being reflected from other | |
on and off. |
| objects may be affecting the |
|
| sensor. |
|
|
|