Rewire To 440V (G9953ZXF Only)
To rewire the Model G9953ZXF to 440V:
1.Disconnect the sander from the power source!
2.Replace the power indicator light in the pedestal switch to one suitable for 440V operation
3.Remove the
7 |
Overload Relay
Figure 4. Overload relays.
4.Remove the CN-18 magnetic contact over- load relay and replace it with a CN-11 type (Figure 5).
Magnetic |
Contactor |
Overload |
Relay |
11 |
Figure 5. Overload relays.
5.Wire the motor as shown on the diagram on the inside of the motor wire cover. Note— The circled references on the diagrams rep- resent labels on the wires. Also, Figure 6 below has been provided for your reference and are current at the time that this manual is being written. However, always use the dia- gram on the wire cover that comes with your motor!
G9953ZXF
Motor Wiring
4 | 5 | 6 | 4 | 5 | 6 |
7 | 8 | 9 | 7 | 8 | 9 |
1 | 2 | 3 | 1 | 2 | 3 |
R S T | R S T |
220V | 440V |
Figure 6. 440V motor wiring.
|
|
|
|
|
|
|
|
|
|
|
|