Use only three wire extension cords that have
Repair or replace a damaged or worn cord immediately.
Make sure the voltage of your power supply matches the specifications on the motor plate of the Jointer.
Extension cords
The use of an extension cord is not recommended for the PJ882 Jointer. But if one is necessary, make sure the cord rating is suitable for the amperage listed on the machine’s motor plate. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating.
Use the chart in Figure 8 as a general guide in choosing the correct size cord. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.
230 Volt, Single Phase Operation
As received from the factory, the
You may either connect a UL/CSA listed 230V plug (similiar to the one shown in Figure 9) or
If the Jointer is to be
The Jointer with a 230 volt plug should only be connected to an outlet having the same configuration. No adapter is available or should be used with the 230 volt plug.
Three Phase Operation
The
You may either connect a UL/CSA listed plug, or
Recommended Gauges (AWG) of Extension Cords
|
| Extension Cord Length * |
| |||
|
|
|
|
|
|
|
Amps | 25 | 50 | 75 | 100 | 150 | 200 |
feet | feet | feet | feet | feet | feet | |
|
|
|
|
|
|
|
< 5 | 16 | 16 | 16 | 14 | 12 | 12 |
|
|
|
|
|
|
|
5 to 8 | 16 | 16 | 14 | 12 | 10 | NR |
|
|
|
|
|
|
|
8 to 12 | 14 | 14 | 12 | 10 | NR | NR |
|
|
|
|
|
|
|
12 to 15 | 12 | 12 | 10 | 10 | NR | NR |
|
|
|
|
|
|
|
15 to 20 | 10 | 10 | 10 | NR | NR | NR |
|
|
|
|
|
|
|
21 to 30 | 10 | NR | NR | NR | NR | NR |
|
|
|
|
|
|
|
*based on limiting the line voltage drop to 5V at 150% of the rated amperes.
NR: Not Recommended.
Figure 8
Figure 9
12