SECTION 2: CIRCUIT REQUIREMENTS

220V Single-Phase

The Model G5959Z has a 5 HP, 3450 RPM motor which requires a 220V single-phase circuit. The cord set included does not have a plug, as the style of plug you require will depend upon the type of service you currently have or plan to install. The motor will safely draw about 30 amps at 220V under load. If you operate the Model G5959Z on any circuit that is already close to its capacity, it might blow a fuse or trip a circuit breaker. However, if an unusual load does not exist, and power failure still occurs, have the circuit inspect- ed by a qualified electrician.

The Model G5959Z should be fused at 30 amps. Fusing at amperage ratings higher than 30 amps will not adequately protect the circuit. Make sure that existing electrical wires are capable of han- dling a 30 amp current. If unsure, seek the assis- tance of a qualified electrician.

Figure 5. 220V Single-Phase.

In preparing to connect the Model G5959Z to your existing or new circuit, it will be necessary to con- nect a plug that matches your 220V receptacle. If you will be installing a new receptacle and plug, we recommend using a NEMA-style 6L-30 plug and outlet shown in Figure 5.

-8-

G5959Z 12" Left-Tilting Table Saw

Page 10
Image 10
Grizzly G5959Z instruction manual Circuit Requirements, 220V Single-Phase