Bryant 697C warranty 41,000

Page 12

COMBINATION RATINGS* Continued

 

 

 

 

 

 

ARI STANDARD RATINGS*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT SIZE-

 

 

 

Cooling

 

 

 

 

 

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Seasonal Efficiency SEER

 

 

 

 

 

 

 

 

SERIES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AND

 

 

Factory-

 

Field-Supplied

 

High-Temp

 

Low-Temp

 

Seasonal

SOUND

 

 

Supplied

 

Accessory‡

 

 

 

 

 

 

 

Efficiency

RATING

INDOOR

 

Enhance-

Standard

 

 

 

 

 

 

 

 

 

 

HSPF/HSPF

 

 

 

 

 

TC

COP

 

TC

COP

 

(dBA)

UNIT

TC

ment

Rating

TXV

 

TXV&TDR**

 

 

with LSV

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COILS + 355MAV042040 VARIABLE-SPEED FURNACE

 

 

 

 

 

 

CC5A/CD5A/CD5BA042

34,400

TDR

12.50

 

 

36,000

3.40

 

22,400

2.46

 

7.80/—

 

CD3(A,B)A042

34,400

TDR

12.50

 

 

36,000

3.40

 

22,400

2.46

 

7.80/—

 

CJ5A/CK5A/CK5BA042

34,400

TDR

12.50

 

 

36,000

3.44

 

22,400

2.48

 

8.00

 

CJ5A/CK5A/CK5BW036

34,400

TDR

12.00

 

 

36,000

3.40

 

22,600

2.46

 

7.80

 

CK3BA036

34,400

TDR

12.00

 

 

36,000

3.40

 

22,600

2.46

 

7.80

 

CK3BA042

34,400

TDR

12.50

 

 

36,000

3.44

 

22,400

2.48

 

8.00

 

 

 

COILS + 355MAV042060 VARIABLE-SPEED FURNACE

 

 

 

 

 

 

CC5A/CD5A/CD5BA042

34,400

TDR

12.50

 

 

36,000

3.40

 

22,400

2.46

 

7.80/—

 

CD3(A,B)A042

34,400

TDR

12.50

 

 

36,000

3.40

 

22,400

2.46

 

7.80/—

 

CJ5A/CK5A/CK5BA036

34,400

TDR

12.00

 

 

36,000

3.40

 

22,400

2.46

 

7.80

 

CJ5A/CK5A/CK5BN042

34,400

TDR

12.50

 

 

36,000

3.44

 

22,400

2.48

 

8.00

 

CK3BA036

34,400

TDR

12.00

 

 

36,000

3.40

 

22,400

2.46

 

7.80

 

CK3BA042

34,400

TDR

12.50

 

 

36,000

3.44

 

22,400

2.48

 

8.00

036-B

 

 

COILS + 355MAV042080 VARIABLE-SPEED FURNACE

 

 

 

 

 

CC5A/CD5A/CD5BA042

34,600

TDR

12.70

 

 

35,800

3.44

 

22,200

2.50

 

7.80/—

 

 

 

 

 

 

CD3(A,B)A042

34,600

TDR

12.70

 

 

35,800

3.44

 

22,200

2.50

 

7.80/—

74

CJ5A/CK5A/CK5BA042

34,600

TDR

12.50

 

 

36,000

3.46

 

22,200

2.50

 

8.00

 

CJ5A/CK5A/CK5BW036

34,400

TDR

12.50

 

 

36,000

3.42

 

22,400

2.48

 

8.00

 

CK3BA036

34,400

TDR

12.50

 

 

36,000

3.42

 

22,400

2.48

 

8.00

 

CK3BA042

34,600

TDR

12.50

 

 

36,000

3.46

 

22,200

2.50

 

8.00

 

 

 

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

 

 

 

 

 

 

CC5A/CD5A/CD5BA042

34,600

TDR

12.70

 

 

35,800

3.44

 

22,200

2.50

 

7.80/—

 

CD3(A,B)A042

34,600

TDR

12.70

 

 

35,800

3.44

 

22,200

2.50

 

7.80/—

 

CJ5A/CK5A/CK5BA042

34,600

TDR

12.80

 

 

35,800

3.50

 

22,200

2.54

 

8.00

 

CJ5A/CK5A/CK5BW036

34,600

TDR

12.50

 

 

36,000

3.48

 

22,200

2.50

 

8.00

 

CK3BA036

34,600

TDR

12.50

 

 

36,000

3.48

 

22,200

2.50

 

8.00

 

CK3BA042

34,600

TDR

12.80

 

 

35,800

3.50

 

22,200

2.54

 

8.00

 

 

 

COILS + 355MAV060120 VARIABLE-SPEED FURNACE

 

 

 

 

 

 

CJ5A/CK5A/CK5BA042

34,600

TDR

12.80

 

 

35,800

3.50

 

22,200

2.54

 

8.00

 

CJ5A/CK5A/CK5BW036

34,600

TDR

12.50

 

 

35,800

3.48

 

22,200

2.52

 

8.00

 

CK3BA036

34,600

TDR

12.50

 

 

35,800

3.48

 

22,200

2.52

 

8.00

 

CK3BA042

34,600

TDR

12.80

 

 

35,800

3.50

 

22,200

2.54

 

8.00

 

FK4CNF005†

41,000

TDR & TXV

14.00

 

 

41,000

3.72

 

24,800

2.66

 

8.20/8.40

 

F(A,B)4AN(F,B)042

39,000

TDR

12.00

 

 

41,000

3.32

 

25,600

2.40

 

7.50/7.70

 

F(A,B)4AN(F,B)048

39,500

TDR

12.50

 

 

41,000

3.46

 

25,600

2.46

 

7.70/7.90

 

FC4BNF038

40,500

TDR & TXV

12.50

 

 

41,000

3.56

 

25,800

2.50

 

7.80/8.00

 

FC4BN(F,B)042

39,000

TDR & TXV

12.00

 

 

41,000

3.32

 

25,600

2.40

 

7.50/7.70

 

FC4BN(F,B)048

39,500

TDR & TXV

12.50

 

 

41,000

3.46

 

25,600

2.46

 

7.70/7.90

 

FG3AAA048

39,000

None

 

12.00

 

41,000

3.38

 

25,400

2.44

 

7.50/7.70

 

FK4BNB005

41,500

TDR & TXV

13.50

 

 

41,000

3.74

 

25,400

2.62

 

8.20/8.40

 

FK4BNF003

39,500

TDR & TXV

13.00

 

 

41,000

3.44

 

250,00

2.50

 

7.80/8.00

 

FK4CNF003

39,500

TDR & TXV

13.50

 

 

40,000

3.42

 

24,800

2.52

 

7.80/8.00

 

CC5A/CD5A/CD5BA042

39,000

None

 

12.00

 

41,000

3.32

 

25,400

2.40

 

7.50/7.70

 

CC5A/CD5A/CD5BW042

38,500

None

 

12.00

 

41,000

3.28

 

25,400

2.38

 

7.40/7.60

 

CC5A/CD5A/CD5BA043

39,000

None

 

12.00

 

41,000

3.32

 

25,400

2.40

 

7.50/7.70

 

CC5A/CD5A/CD5BW043

39,000

None

 

12.00

 

41,000

3.30

 

25,400

2.40

 

7.50/7.70

 

CD5A/CD5BA048

39,000

None

 

12.50

 

41,000

3.36

 

25,400

2.42

 

7.50/7.70

 

CC5A/CD5A/CD5BC048

38,500

None

 

12.50

 

41,000

3.22

 

25,400

2.38

 

7.30/7.50

 

CC5A/CD5A/CD5BW048

39,000

None

 

12.50

 

41,000

3.36

 

25,400

2.42

 

7.50/7.70

 

CD3(A,B)A042

39,000

None

 

12.00

 

41,000

3.32

 

25,400

2.40

 

7.40/7.60

042-B

CD3(A,B)A048

39,000

None

 

12.50

 

41,000

3.36

 

25,400

2.42

 

7.50/7.70

 

CE3AA042

39,500

None

 

12.00

 

41,000

3.36

 

25,400

2.42

 

7.50/7.70

 

CE3AA048

39,500

None

 

12.50

 

41,000

3.40

 

25,400

2.44

 

7.50/7.70

74

CF5AA048

39,500

None

 

12.50

 

41,000

3.34

 

25,400

2.42

 

7.50/7.50

 

CJ5A/CK5A/CK5BA042

40,000

None

 

12.00

 

41,000

3.34

 

25,600

2.42

 

7.50

 

CJ5A/CK5A/CK5BA048

40,000

None

 

12.00

 

41,000

3.40

 

25,600

2.44

 

7.50

 

CJ5A/CK5A/CK5BN042

40,000

None

 

12.00

 

41,000

3.34

 

25,600

2.42

 

7.50

 

CJ5A/CK5A/CK5BW048

40,000

None

 

12.00

 

41,000

3.40

 

25,600

2.44

 

7.50

 

CK3BA042

40,000

None

 

12.00

 

41,000

3.34

 

25,600

2.42

 

7.50

 

CK3BA048

40,000

None

 

12.00

 

41,000

3.40

 

25,600

2.44

 

7.50

 

 

 

COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE

 

 

 

 

 

 

CD5A/CD5BA048

39,000

TDR

13.00

 

 

40,000

3.28

 

24,600

2.44

 

7.50/7.70

 

CC5A/CD5A/CD5BW048

39,000

TDR

13.00

 

 

40,000

3.28

 

24,600

2.44

 

7.50/7.70

 

CD3(A,B)A048

39,000

TDR

13.00

 

 

40,000

3.28

 

24,600

2.44

 

7.50/7.70

 

CC5A/CD5A/CD5BC048

38,500

TDR

13.00

 

 

40,000

3.24

 

24,800

2.42

 

7.30/7.50

 

CE3AA048

39,500

TDR

13.00

 

 

41,000

3.44

 

25,000

2.50

 

7.50/7.70

 

 

 

COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE

 

 

 

 

 

 

CD5A/CD5BA048

39,000

TDR

13.00

 

 

40,000

3.28

 

24,600

2.44

 

7.50/7.70

 

CC5A/CD5A/CD5BW048

39,000

TDR

13.00

 

 

40,000

3.28

 

24,600

2.44

 

7.50/7.70

 

CD3(A,B)A048

39,000

TDR

13.00

 

 

40,000

3.28

 

24,600

2.44

 

7.50/7.70

 

CC5A/CD5A/CD5BC048

38,500

TDR

13.00

 

 

40,000

3.26

 

24,800

2.42

 

7.30/7.50

 

CE3AA048

39,500

TDR

13.50

 

 

41,000

3.44

 

25,000

2.52

 

7.50/7.70

 

CJ5A/CK5A/CK5BA042

40,000

TDR

13.00

 

 

41,000

3.44

 

25,200

2.48

 

7.50

 

CJ5A/CK5A/CK5BA048

40,000

TDR

13.20

 

 

41,000

3.50

 

25,200

2.52

 

7.70

See notes on page 15.

—12—

Image 12
Contents 697C 60 HZ Dimensions Recommended Tube Diameters Specifications Specifications Accessory Usage Guideline Secondary Outdoor Thermostat Combination Ratings Combination Ratings Accessory‡ Efficiency Coils + 355MAV060120 VARIABLE-SPEED Furnace 41,000 47,500 59,000 11.20 697C Balance Point Worksheet Detailed Cooling Capacities 697C018-B Outdoor Section With FC4BNF024 Indoor SectionDetailed Cooling Capacities 697C024-B Outdoor Section With FC4BNF030 Indoor Section697C030-B Outdoor Section With FC4BNF036 Indoor Section Coils + 355MAV060120 VARIABLE-SPEED Furnace 697C036-B Outdoor Section With FC4BNF,B042 Indoor Section CJ5AS/CK5A/CK5BW 697C042-B Outdoor Section With FK4CNF005 Indoor Section Detailed Cooling Capacities Size Capacity Power 697C048-A Outdoor Section With FK4CNF005 Indoor Section697C060-A Outdoor Section With FK4CNB006 Indoor Section Heat Pump Heating Performance Heat Pump Heating Performance Coils + 355MAV0601020 VARIABLE-SPEED Furnace Coils ± 333B,JAV060120 VARIABLE-SPEED Furnace Heat Pump Heating Performance Indoor Heating Section Size Capacity Power Indoor Heating Section CK5A/CK5A/CK5BX System Design Service Training