Bryant 697C warranty Coils + 355MAV0601020 VARIABLE-SPEED Furnace

Page 29

HEAT PUMP HEATING PERFORMANCE Continued

 

INDOOR

 

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

–3

 

 

7

 

 

17

 

 

27

 

 

37

 

 

47

 

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

 

 

 

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

 

 

EDB

CFM

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

697C030-B Outdoor Section With FC4BNF036 Indoor Section

 

 

 

 

 

 

 

 

850

12.9

11.9

2.08

15.5

14.2

2.17

18.5

16.8

2.27

21.9

19.4

2.38

25.7

23.4

2.52

30.0

30.0

2.69

34.9

34.9

2.91

 

 

65

950

13.1

12.0

2.11

15.7

14.4

2.19

18.7

17.0

2.29

22.1

19.6

2.39

26.0

23.7

2.53

30.4

30.4

2.69

35.2

35.2

2.91

 

 

 

1050

13.2

12.2

2.14

15.9

14.6

2.22

18.9

17.2

2.31

22.3

19.8

2.41

26.2

23.9

2.54

30.6

30.6

2.71

35.5

35.5

2.91

 

 

 

850

12.7

11.7

2.16

15.4

14.1

2.26

18.3

16.7

2.36

21.6

19.2

2.48

25.4

23.1

2.62

29.7

29.7

2.80

34.5

34.5

3.03

 

 

70

950

12.9

11.9

2.19

15.5

14.3

2.28

18.5

16.9

2.38

21.9

19.4

2.49

25.7

23.4

2.63

30.0

30.0

2.80

34.8

34.8

3.02

 

 

 

1050

13.1

12.0

2.22

15.7

14.4

2.31

18.7

17.0

2.40

22.1

19.6

2.51

25.9

23.6

2.64

30.3

30.3

2.81

35.1

35.1

3.02

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

850

12.5

11.5

2.24

15.3

14.0

2.35

18.1

16.5

2.46

21.4

19.0

2.58

25.1

22.9

2.74

29.4

29.4

2.92

34.1

34.1

3.15

 

 

75

950

12.7

11.7

2.27

15.4

14.2

2.37

18.3

16.7

2.47

21.6

19.2

2.59

25.4

23.1

2.73

29.7

29.7

2.91

34.4

34.4

3.14

 

 

 

1050

12.9

11.9

2.30

15.6

14.3

2.40

18.5

16.9

2.50

21.8

19.4

2.61

25.6

23.3

2.74

29.9

29.9

2.92

34.7

34.7

3.14

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

 

 

Heating

Indoor

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

Section

Size

Capacity

 

Power

Section

Size

Capacity

 

Power

 

 

FC4BNF

030

1.00

 

1.01

CD5A/CD5BW

036

0.97

 

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

033

1.00

 

0.98

CD3(A,B)A

036

0.97

 

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

1.00

 

1.00

CE3AA

036

0.97

 

0.93

 

 

 

 

 

 

 

 

 

 

 

 

 

F(A,B)4ANF

030

1.00

 

1.01

COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE

 

 

 

036

1.00

 

1.00

CC5A/CD5A/CD5BA

036

0.97

 

0.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FD3ANA

030

1.00

 

1.01

CD5A/CD5BW

036

0.97

 

0.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FF1(A,B)NA

030

1.00

 

0.99

CD3(A,B)A

036

0.97

 

0.93

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FG3AAA

036

1.00

 

1.01

CE3AA

036

0.97

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

FK4BNF

001

1.00

 

0.96

COILS + 355MAV042040 VARIABLE-SPEED FURNACE

 

 

 

002

1.00

 

0.92

CC5A/CD5A/CD5BA

036

1.00

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

003

0.99

 

0.91

CD5A/CD5BW

036

1.00

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

004

1.00

 

0.88

CD3(A,B)A

036

1.00

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FK4CNF

001

0.99

 

0.94

CJ5A/CK5A/CK5BW

030

0.98

 

0.97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

002

0.99

 

0.92

 

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

003

0.99

 

0.92

CK3BA

030

0.98

 

0.97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CC5A/CD5A/CD5BA

030

1.00

 

1.05

 

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

1.00

 

0.99

COILS + 355MAV042060 VARIABLE-SPEED FURNACE

 

 

CC5A/CD5A/CD5BW

030

1.00

 

1.05

CC5A/CD5A/CD5BA

036

1.00

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CD5A/CD5BW

036

1.00

 

0.99

CD5A/CD5BW

036

1.00

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CD3(A,B)A

030

1.00

 

1.05

CD3(A,B)A

036

1.00

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

1.00

 

0.99

CJ5A/CK5A/CK5BA

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE3AA

030

1.00

 

1.01

CJ5A/CK5A/CK5BW

030

0.98

 

0.97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

1.00

 

1.01

CK3BA

030

0.98

 

0.97

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CF5AA

036

1.00

 

0.99

 

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ5A/CK5A/CK5BA

030

0.98

 

1.01

COILS + 355MAV042080 VARIABLE-SPEED FURNACE

 

 

 

036

1.00

 

0.98

CC5A/CD5A/CD5BA

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ5A/CK5A/CK5BW

030

0.98

 

1.01

CD5A/CD5BW

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

1.00

 

0.98

CD3(A,B)A

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CK3BA

030

0.98

 

1.01

CJ5A/CK5A/CK5BW

030

0.97

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

036

1.00

 

0.98

 

036

0.98

 

0.92

 

 

 

 

 

 

 

 

 

 

 

 

 

COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE

CK3BA

030

0.97

 

0.95

 

 

CC5A/CD5A/CD5BA

036

0.97

 

0.93

 

036

0.98

 

0.92

 

 

 

 

 

 

 

 

 

 

 

 

 

CD5A/CD5BW

036

0.97

 

0.93

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

 

 

CD3(A,B)A

036

0.97

 

0.93

CC5A/CD5A/CD5BA

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE3AA

036

0.97

 

0.95

CD5A/CD5BW

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ5A/CK5A/CK5BA

030

0.97

 

0.95

CD3(A,B)A

036

1.00

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ5A/CK5A/CK5BW

030

0.97

 

0.95

CJ5A/CK5A/CK5BW

030

0.97

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CK3BA

030

0.97

 

0.95

 

036

0.98

 

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE

CK3BA

030

0.97

 

0.94

 

 

CC5A/CD5A/CD5BA

036

0.97

 

0.92

 

036

0.98

 

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

CD5A/CD5BW

036

0.97

 

0.92

COILS + 355MAV0601020 VARIABLE-SPEED FURNACE

 

 

CD3(A,B)A

036

0.97

 

0.92

CJ5A/CK5A/CK5BW

030

0.97

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CE3AA

036

0.97

 

0.94

 

036

0.98

 

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ5A/CK5A/CK5BW

030

0.97

 

0.95

CK3BA

030

0.97

 

0.94

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CK3BA

030

0.97

 

0.95

 

036

0.98

 

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE

 

 

 

 

CC5A/CD5A/CD5BA

036

0.97

 

0.91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See notes on page 34.

—29—

Image 29
Contents 697C 60 HZ Dimensions Recommended Tube Diameters Specifications Specifications Accessory Usage Guideline Secondary Outdoor Thermostat Combination Ratings Combination Ratings Accessory‡ Efficiency Coils + 355MAV060120 VARIABLE-SPEED Furnace 41,000 47,500 59,000 11.20 697C Balance Point Worksheet 697C018-B Outdoor Section With FC4BNF024 Indoor Section Detailed Cooling Capacities697C024-B Outdoor Section With FC4BNF030 Indoor Section Detailed Cooling Capacities697C030-B Outdoor Section With FC4BNF036 Indoor Section Coils + 355MAV060120 VARIABLE-SPEED Furnace 697C036-B Outdoor Section With FC4BNF,B042 Indoor Section CJ5AS/CK5A/CK5BW 697C042-B Outdoor Section With FK4CNF005 Indoor Section Detailed Cooling Capacities 697C048-A Outdoor Section With FK4CNF005 Indoor Section Size Capacity Power697C060-A Outdoor Section With FK4CNB006 Indoor Section Heat Pump Heating Performance Heat Pump Heating Performance Coils + 355MAV0601020 VARIABLE-SPEED Furnace Coils ± 333B,JAV060120 VARIABLE-SPEED Furnace Heat Pump Heating Performance Indoor Heating Section Size Capacity Power Indoor Heating Section CK5A/CK5A/CK5BX System Design Service Training