Bryant 697C warranty Heat Pump Heating Performance

Page 31

HEAT PUMP HEATING PERFORMANCE Continued

 

INDOOR

 

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

–3

 

 

7

 

 

17

 

 

27

 

 

37

 

 

47

 

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

 

 

 

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

 

 

EDB

CFM

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

697C036-B Outdoor Section With FC4BN(F,B)042 Indoor Section Continued

 

 

 

 

 

 

 

1100

16.0

14.7

2.43

19.3

17.7

2.53

22.8

20.8

2.64

26.7

23.7

2.74

31.2

28.4

2.87

36.1

36.1

3.03

41.8

41.8

3.23

 

 

65

1200

16.2

14.9

2.46

19.4

17.9

2.55

23.0

21.0

2.65

26.9

23.9

2.75

31.4

28.6

2.87

36.4

36.4

3.03

42.1

42.1

3.22

 

 

 

1300

16.4

15.1

2.48

19.7

18.1

2.58

23.2

21.1

2.66

27.1

24.1

2.76

31.6

28.7

2.88

36.6

36.6

3.03

42.4

42.4

3.22

 

 

 

1100

15.7

14.5

2.52

19.1

17.5

2.64

22.6

20.6

2.75

26.5

23.5

2.87

30.9

28.1

3.00

35.7

35.7

3.17

41.3

41.3

3.37

 

 

70

1200

15.9

14.6

2.55

19.2

17.7

2.66

22.8

20.8

2.76

26.7

23.7

2.87

31.1

28.3

3.00

36.0

36.0

3.16

41.6

41.6

3.36

 

 

 

1300

16.1

14.8

2.57

19.4

17.8

2.68

23.0

20.9

2.78

26.9

23.9

2.88

31.3

28.5

3.01

36.2

36.2

3.16

41.9

41.9

3.35

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1100

15.4

14.1

2.62

18.9

17.3

2.74

22.4

20.4

2.87

26.2

23.3

2.99

30.6

27.8

3.14

35.4

35.4

3.31

40.9

40.9

3.52

 

 

75

1200

15.6

14.3

2.64

19.0

17.5

2.76

22.6

20.6

2.88

26.4

23.5

3.00

30.8

28.0

3.14

35.6

35.6

3.30

41.2

41.2

3.50

 

 

 

1300

15.7

14.5

2.67

19.2

17.6

2.78

22.7

20.7

2.89

26.6

23.6

3.01

31.0

28.2

3.14

35.9

35.9

3.30

41.5

41.5

3.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

 

 

Heating

Indoor

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

Section

Size

Capacity

 

Power

Section

Size

Capacity

 

Power

 

 

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

COILS + 355MAV060120 VARIABLE-SPEED FURNACE

 

 

CC5A/CD5A/CD5BA

042

0.99

 

0.97

CJ5A/CK5A/CK5BA

042

0.99

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CD3(A,B)A

042

0.99

 

0.97

CJ5A/CK5A/CK5BW

036

0.99

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ5A/CK5A/CK5BA

042

0.99

 

0.95

CK3BA

036

0.99

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CJ5A/CK5A/CK5BW

036

1.00

 

0.96

 

042

0.99

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CK3BA

036

1.00

 

0.96

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

042

0.99

 

0.95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

See notes on page 34.

—31—

Image 31
Contents 697C 60 HZ Dimensions Recommended Tube Diameters Specifications Specifications Accessory Usage Guideline Secondary Outdoor Thermostat Combination Ratings Combination Ratings Accessory‡ Efficiency Coils + 355MAV060120 VARIABLE-SPEED Furnace 41,000 47,500 59,000 11.20 697C Balance Point Worksheet 697C018-B Outdoor Section With FC4BNF024 Indoor Section Detailed Cooling Capacities697C024-B Outdoor Section With FC4BNF030 Indoor Section Detailed Cooling Capacities697C030-B Outdoor Section With FC4BNF036 Indoor Section Coils + 355MAV060120 VARIABLE-SPEED Furnace 697C036-B Outdoor Section With FC4BNF,B042 Indoor Section CJ5AS/CK5A/CK5BW 697C042-B Outdoor Section With FK4CNF005 Indoor Section Detailed Cooling Capacities 697C048-A Outdoor Section With FK4CNF005 Indoor Section Size Capacity Power697C060-A Outdoor Section With FK4CNB006 Indoor Section Heat Pump Heating Performance Heat Pump Heating Performance Coils + 355MAV0601020 VARIABLE-SPEED Furnace Coils ± 333B,JAV060120 VARIABLE-SPEED Furnace Heat Pump Heating Performance Indoor Heating Section Size Capacity Power Indoor Heating Section CK5A/CK5A/CK5BX System Design Service Training