Bryant Comprehensive Heating Performance Guide for FK4CNB006 Heat Pump

Page 34

HEAT PUMP HEATING PERFORMANCE Continued

 

INDOOR

 

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

–3

 

 

7

 

 

17

 

 

27

 

 

37

 

 

47

 

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

 

 

 

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

 

 

EDB

CFM

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

697C060-A Outdoor Section With FK4CNB006 Indoor Section

 

 

 

 

 

 

 

65

1575

28.0

25.8

3.81

33.2

30.6

4.02

39.1

35.6

4.24

45.3

40.3

4.4

52.8

48.0

4.81

61.2

61.2

5.20

71.0

71.0

5.73

 

 

1750

28.3

26.0

3.82

33.5

30.8

4.01

39.4

35.9

4.22

45.7

40.5

4.4

53.2

48.4

4.76

61.7

61.7

5.14

71.7

71.7

5.65

 

 

 

2012

28.6

26.3

3.84

33.9

31.1

4.02

39.7

36.2

4.21

46.1

40.9

4.4

53.7

48.9

4.72

62.3

62.3

5.09

72.0

72.0

5.52

 

 

70

1575

27.7

25.5

3.98

32.9

30.3

4.21

38.7

35.3

4.45

44.9

39.8

4.7

52.1

47.5

5.05

60.5

60.5

5.45

70.2

70.2

5.99

 

 

1750

28.0

25.7

3.99

33.2

30.5

4.20

39.0

35.6

4.43

45.2

40.1

4.6

52.6

47.8

4.99

61.0

61.0

5.38

71.6

71.6

5.91

 

 

 

2012

28.3

26.0

4.02

33.5

30.8

4.21

39.4

35.9

4.42

45.6

40.5

4.6

53.1

48.3

4.95

61.6

61.6

5.32

71.5

71.5

5.84

 

 

75

1575

27.4

25.2

4.16

32.6

30.0

4.41

38.3

35.0

4.67

44.4

39.4

4.9

51.6

47.0

5.29

59.8

59.8

5.72

69.3

69.3

6.27

 

 

1750

27.6

25.4

4.16

32.9

30.2

4.40

38.6

35.2

4.64

44.7

39.7

4.9

52.0

47.3

5.23

60.3

60.3

5.64

70.0

70.0

6.17

 

 

 

2012

28.0

25.7

4.19

33.2

30.5

4.41

39.0

35.6

4.63

45.2

40.1

4.8

52.5

47.8

5.18

60.9

60.9

5.57

70.7

70.7

6.10

 

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

 

 

Heating

Indoor

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

Section

Size

Capacity

 

Power

Section

Size

Capacity

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F(A,B)4AN(F,B,C)

060

1.00

 

1.09

CD3(A,B)A

060

1.00

 

1.17

 

 

FB4ANB

070

1.00

 

1.03

CE3AA

060

1.00

 

1.10

 

 

FC4BN(F,B)

060

1.00

 

1.09

CJ5A/CK5A/CK5BA

060

1.00

 

1.12

 

 

FC4BNB

070

1.00

 

1.03

CK5A/CK5A/CK5BX

060

1.00

 

1.06

 

 

FG3AAA

060

1.00

 

1.13

CK3BA

060

1.00

 

1.12

 

 

FK4BNB

006

1.00

 

1.01

COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE

 

 

FK4CNB

006

1.00

 

1.00

CC5A/CD5A/CD5BA

060

1.00

 

1.19

 

 

CC5A/CD5A/CD5BA

060

1.00

 

1.18

CC5A/CD5A/CD5BW

060

1.00

 

1.10

 

 

CC5A/CD5A/CD5BW

060

1.00

 

1.11

CD3(A,B)A

060

1.00

 

1.19

 

 

CD3(A,B)A

060

1.00

 

1.18

CE3AA

060

1.00

 

1.11

 

 

CE3AA

060

1.00

 

1.11

CJ5A/CK5A/CK5BA

060

1.00

 

1.11

 

 

CJ5A/CK5A/CK5BA

060

1.00

 

1.12

CK5A/CK5A/CK5BX

060

1.00

 

1.06

 

 

CJ5A/CK5A/CK5BN

060

1.00

 

1.12

CK3BA

060

1.00

 

1.11

 

 

CJ5A/CK5A/CK5BX

060

1.00

 

1.07

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

 

 

CK3BA

060

1.00

 

1.12

CC5A/CD5A/CD5BA

060

1.00

 

1.19

 

 

COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE

CC5A/CD5A/CD5BW

060

1.00

 

1.11

 

 

CC5A/CD5A/CD5BA

060

1.00

 

1.17

CD3(A,B)A

060

1.00

 

1.19

 

 

CC5A/CD5A/CD5BW

060

1.00

 

1.10

 

 

 

*The Btuh heating capacity values shown are net “integrated’’ values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.

The kw values include the compressor, outdoor fan motor, and indoor blower motor. The kw from supplement heaters should be added to these values to

obtain total system kilowatts. EDB—Entering Dry Bulb

—34—

Image 34
Contents 697C 60 HZ Dimensions Recommended Tube Diameters Specifications Specifications Accessory Usage Guideline Secondary Outdoor Thermostat Combination Ratings Combination Ratings Accessory‡ Efficiency Coils + 355MAV060120 VARIABLE-SPEED Furnace 41,000 47,500 59,000 11.20 697C Balance Point Worksheet Detailed Cooling Capacities 697C018-B Outdoor Section With FC4BNF024 Indoor SectionDetailed Cooling Capacities 697C024-B Outdoor Section With FC4BNF030 Indoor Section697C030-B Outdoor Section With FC4BNF036 Indoor Section Coils + 355MAV060120 VARIABLE-SPEED Furnace 697C036-B Outdoor Section With FC4BNF,B042 Indoor Section CJ5AS/CK5A/CK5BW 697C042-B Outdoor Section With FK4CNF005 Indoor Section Detailed Cooling Capacities Size Capacity Power 697C048-A Outdoor Section With FK4CNF005 Indoor Section697C060-A Outdoor Section With FK4CNB006 Indoor Section Heat Pump Heating Performance Heat Pump Heating Performance Coils + 355MAV0601020 VARIABLE-SPEED Furnace Coils ± 333B,JAV060120 VARIABLE-SPEED Furnace Heat Pump Heating Performance Indoor Heating Section Size Capacity Power Indoor Heating Section CK5A/CK5A/CK5BX System Design Service Training