Bryant 697C warranty Indoor Heating Section Size Capacity Power

Page 32

HEAT PUMP HEATING PERFORMANCE Continued

 

INDOOR

 

 

 

 

 

 

OUTDOOR COIL ENTERING AIR TEMPERATURES °F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIR

 

–3

 

 

7

 

 

17

 

 

27

 

 

37

 

 

47

 

 

57

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

 

 

 

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

(MBtuh)

Pwr

 

 

EDB

CFM

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

Total

Int*

Kw†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

697C042-B Outdoor Section With FK4CNF005 Indoor Section

 

 

 

 

 

 

 

65

1103

17.2

15.8

2.38

20.8

19.2

2.50

24.9

22.7

2.62

29.3

26.0

2.7

34.5

31.4

2.92

40.5

40.5

3.12

47.4

47.4

3.36

 

 

1225

17.3

16.0

2.38

21.0

19.3

2.49

25.0

22.8

2.60

29.5

26.2

2.7

34.8

31.6

2.88

40.8

40.8

3.07

47.5

47.5

3.27

 

 

 

1409

17.5

16.1

2.39

21.1

19.4

2.48

25.2

23.0

2.59

29.7

26.4

2.7

35.1

31.9

2.85

41.1

41.1

3.03

47.2

47.2

3.18

 

 

70

1103

16.9

15.6

2.49

20.7

19.0

2.62

24.7

22.5

2.75

29.0

25.8

2.9

34.1

31.1

3.07

40.0

40.0

3.28

46.8

46.8

3.54

 

 

1225

17.1

15.7

2.49

20.8

19.1

2.61

24.8

22.6

2.73

29.2

25.9

2.8

34.4

31.3

3.03

41.0

41.0

3.23

47.2

47.2

3.45

 

 

 

1409

17.3

15.9

2.49

21.0

19.3

2.61

25.0

22.8

2.72

29.4

26.1

2.8

34.7

31.6

2.99

40.7

40.7

3.17

47.4

47.4

3.37

 

 

75

1103

16.6

15.3

2.60

20.5

18.8

2.75

24.5

22.3

2.89

28.8

25.5

3.0

33.8

30.8

3.22

39.5

39.5

3.44

46.3

46.3

3.72

 

 

1225

16.8

15.4

2.59

20.6

18.9

2.74

24.6

22.4

2.87

28.9

25.7

3.0

34.0

31.0

3.18

40.8

40.8

3.39

46.6

46.6

3.64

 

 

 

1409

17.0

15.6

2.60

20.8

19.1

2.73

24.8

22.6

2.85

29.2

25.9

2.9

34.3

31.2

3.14

40.8

40.8

3.33

47.1

47.1

3.55

 

Multipliers for Determining the Performance With Other Indoor Sections

 

Indoor

 

 

Heating

Indoor

 

 

Heating

 

 

 

 

 

 

 

 

 

 

 

 

Section

Size

Capacity

 

Power

Section

Size

Capacity

 

Power

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F(A,B)4AN(F,B,C)

042

1.00

 

1.12

CC5A/CD5A/CD5BW

048

0.98

 

1.09

 

 

 

048

1.00

 

1.07

CD3(A,B)A

048

0.98

 

1.09

 

 

FC4BN(F,B)

042

1.00

 

1.12

CD5A/CD5BA

048

0.98

 

1.09

 

 

 

048

1.00

 

1.07

CE3AA

048

1.00

 

1.06

 

 

FC4BNF

038

1.00

 

1.04

CJ5A/CK5A/CK5BA

042

0.98

 

1.04

 

 

FG3AAA

048

1.00

 

1.10

CJ5A/CK5A/CK5BW

048

1.00

 

1.05

 

 

FK4BNB

003

1.00

 

1.08

CK3BA

042

0.98

 

1.04

 

 

FK4BNF

005

1.00

 

0.99

 

048

1.00

 

1.05

 

 

FK4CNF

003

0.98

 

1.06

COILS + 333(B,J)AV060120 VARIABLE-SPEED FURNACE

 

 

 

005

1.00

 

1.00

CC5A/CD5A/CD5BC

048

0.98

 

1.10

 

 

CC5A/CD5A/CD5BA

042

1.00

 

1.12

CC5A/CD5A/CD5BW

048

0.98

 

1.10

 

 

 

043

1.00

 

1.12

CD3(A,B)A

048

0.98

 

1.10

 

 

CC5A/CD5A/CD5BC

048

1.00

 

1.15

CD5A/CD5BA

048

0.98

 

1.10

 

 

CC5A/CD5A/CD5BW

042

1.00

 

1.13

CE3AA

048

1.00

 

1.07

 

 

 

043

1.00

 

1.12

CJ5A/CK5A/CK5BA

042

1.00

 

1.07

 

 

 

048

1.00

 

1.10

CJ5A/CK5A/CK5BW

048

1.00

 

1.05

 

 

CD3(A,B)A

042

1.00

 

1.12

CK3BA

042

1.00

 

1.07

 

 

 

048

1.00

 

1.10

 

048

1.00

 

1.05

 

 

CD5A/CD5BA

048

1.00

 

1.10

COILS + 355MAV042040 VARIABLE-SPEED FURNACE

 

 

CE3AA

042

1.00

 

1.10

CD3(A,B)A

048

1.00

 

1.14

 

 

 

048

1.00

 

1.09

CD5A/CD5BA

048

1.00

 

1.14

 

 

CF5AA

048

1.00

 

1.11

CJ5A/CK5A/CK5BW

048

1.02

 

1.11

 

 

CJ5A/CK5A/CK5BA

042

1.00

 

1.12

CK3BA

048

1.02

 

1.11

 

 

 

048

1.00

 

1.10

COILS + 355MAV042060 VARIABLE-SPEED FURNACE

 

 

CJ5A/CK5A/CK5BN

042

1.00

 

1.12

CD3(A,B)A

048

1.00

 

1.14

 

 

CJ5A/CK5A/CK5BW

048

1.00

 

1.10

CD5A/CD5BA

048

1.00

 

1.14

 

 

CK3BA

042

1.00

 

1.12

CK3BA

048

1.02

 

1.11

 

 

 

048

1.00

 

1.10

COILS + 355MAV042080 VARIABLE-SPEED FURNACE

 

 

COILS + 333(B,J)AV036060 VARIABLE-SPEED FURNACE

CD3(A,B)A

048

1.00

 

1.12

 

 

CC5A/CD5A/CD5BC

048

0.98

 

1.12

CD5A/CD5BA

048

1.00

 

1.12

 

 

CC5A/CD5A/CD5BW

048

0.98

 

1.10

CJ5A/CK5A/CK5BA

042

1.02

 

1.13

 

 

CD3(A,B)A

048

0.98

 

1.10

 

048

1.02

 

1.09

 

 

CD5A/CD5BA

048

0.98

 

1.10

CK3BA

042

1.02

 

1.13

 

 

CE3AA

048

1.00

 

1.08

 

048

1.02

 

1.09

 

 

COILS + 333(B,J)AV048080 VARIABLE-SPEED FURNACE

COILS + 355MAV060100 VARIABLE-SPEED FURNACE

 

 

CC5A/CD5A/CD5BC

048

0.98

 

1.11

CD3(A,B)A

048

1.00

 

1.11

 

 

CC5A/CD5A/CD5BW

048

0.98

 

1.10

CD5A/CD5BA

048

1.00

 

1.11

 

 

CD3(A,B)A

048

0.98

 

1.10

CJ5A/CK5A/CK5BA

042

1.00

 

1.08

 

 

CD5A/CD5BA

048

0.98

 

1.10

 

048

1.00

 

1.06

 

 

CE3AA

048

1.00

 

1.08

CK3BA

042

1.00

 

1.08

 

 

CJ5A/CK5A/CK5BA

042

1.00

 

1.09

 

048

1.00

 

1.06

 

 

 

048

1.00

 

1.07

COILS + 355MAV060120 VARIABLE-SPEED FURNACE

 

 

CK3BA

042

1.00

 

1.09

CJ5A/CK5A/CK5BA

042

1.00

 

1.08

 

 

 

048

1.00

 

1.07

CJ5A/CK5A/CK5BW

048

1.00

 

1.06

 

 

COILS + 333(B,J)AV060100 VARIABLE-SPEED FURNACE

CK3BA

042

1.00

 

1.08

 

 

CC5A/CD5A/CD5BC

048

0.98

 

1.10

 

048

1.00

 

1.06

 

See notes on page 34.

—32—

Image 32
Contents 697C 60 HZ Dimensions Recommended Tube Diameters Specifications Specifications Accessory Usage Guideline Secondary Outdoor Thermostat Combination Ratings Combination Ratings Accessory‡ Efficiency Coils + 355MAV060120 VARIABLE-SPEED Furnace 41,000 47,500 59,000 11.20 697C Balance Point Worksheet Detailed Cooling Capacities 697C018-B Outdoor Section With FC4BNF024 Indoor SectionDetailed Cooling Capacities 697C024-B Outdoor Section With FC4BNF030 Indoor Section697C030-B Outdoor Section With FC4BNF036 Indoor Section Coils + 355MAV060120 VARIABLE-SPEED Furnace 697C036-B Outdoor Section With FC4BNF,B042 Indoor Section CJ5AS/CK5A/CK5BW 697C042-B Outdoor Section With FK4CNF005 Indoor Section Detailed Cooling Capacities Size Capacity Power 697C048-A Outdoor Section With FK4CNF005 Indoor Section697C060-A Outdoor Section With FK4CNB006 Indoor Section Heat Pump Heating Performance Heat Pump Heating Performance Coils + 355MAV0601020 VARIABLE-SPEED Furnace Coils ± 333B,JAV060120 VARIABLE-SPEED Furnace Heat Pump Heating Performance Indoor Heating Section Size Capacity Power Indoor Heating Section CK5A/CK5A/CK5BX System Design Service Training