Bryant 697C warranty Secondary Outdoor Thermostat

Page 7

ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued

13.Secondary Outdoor Thermostat

An SPDT temperature actuated switch which turns on a third stage of supplemental electric heaters when outdoor air temperature drops below the second-

stage set point.

SUGGESTED USE: Heat pump installations where 3-stage operation of supplemental heaters is desired.

14.Service Alarm

A current-sensing lockout relay which provides immediate notification that compressor is not operating during a call for heating or cooling. Used with proper room thermostat, the thermostat light is turned on signifying service is required. This can minimize electrical cost increase due to operation of supplemental heaters only.

SUGGESTED USE: As a feature to notify owner immediately when the system is not operating most efficiently.

15.Snow Stand

Coated wire rack which supports unit 18 in. above mounting pad to allow for drainage from unit base.

SUGGESTED USE: Heat pump installations in heavy snowfall areas.

Heat pump installations in snowdrift locations.

Heat pump installations in areas of prolonged subfreezing temperatures.

All commercial installations.

16.Sound Hood

Wraparound sound reducing cover for the compressor. Reduces unit sound level by about 2 dBA.

SUGGESTED USE: Unit installed closer than 15 ft to quiet areas—bedrooms, etc.

Unit installed between 2 houses less than 10 ft apart.

17.Support Feet

Four stick-on plastic feet which raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base; minimizes corrosion.

SUGGESTED USE: Coastal installations.

Windy areas or where debris is normally circulating.

Rooftop installations.

18.Thermostatic Expansion Valve (TXV)—Bi-flow

A modulating flow control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evap- orator. Kit includes valve, adapter tubes, and external equalizer tube.

SUGGESTED USE: Required for improved system performance. (Refer to ARI Unitary Directory.)

Required for use on all zoning systems.

19.Time-Delay Relay

An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off.

SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. (Refer to ARI Unitary Directory.)

—7—

Image 7
Contents 697C 60 HZ Dimensions Recommended Tube Diameters Specifications Specifications Accessory Usage Guideline Secondary Outdoor Thermostat Combination Ratings Combination Ratings Accessory‡ Efficiency Coils + 355MAV060120 VARIABLE-SPEED Furnace 41,000 47,500 59,000 11.20 697C Balance Point Worksheet 697C018-B Outdoor Section With FC4BNF024 Indoor Section Detailed Cooling Capacities697C024-B Outdoor Section With FC4BNF030 Indoor Section Detailed Cooling Capacities697C030-B Outdoor Section With FC4BNF036 Indoor Section Coils + 355MAV060120 VARIABLE-SPEED Furnace 697C036-B Outdoor Section With FC4BNF,B042 Indoor Section CJ5AS/CK5A/CK5BW 697C042-B Outdoor Section With FK4CNF005 Indoor Section Detailed Cooling Capacities 697C048-A Outdoor Section With FK4CNF005 Indoor Section Size Capacity Power697C060-A Outdoor Section With FK4CNB006 Indoor Section Heat Pump Heating Performance Heat Pump Heating Performance Coils + 355MAV0601020 VARIABLE-SPEED Furnace Coils ± 333B,JAV060120 VARIABLE-SPEED Furnace Heat Pump Heating Performance Indoor Heating Section Size Capacity Power Indoor Heating Section CK5A/CK5A/CK5BX System Design Service Training