temperature display.
TROUBLESHOOTING GUIDE
ELECTRIC OVENS
MODEL | 400/230 VAC | 50 HZ. | 3 PHASE | |
REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS | ||||
|
|
|
| |
SYMPTOM | POSSIBLE CAUSE | EVALUATION |
| |
Oven fan will not run | Incoming power supply | Check circuit breakers. Reset if required. Call | ||
|
|
| power company if needed. | |
| Oven cavity | Terminals are normally closed. If open, reset | ||
| thermostat |
| and test oven for proper operation. If | |
|
|
| thermostat will not hold for maximum oven | |
|
|
| temperature, and oven is not exceeding | |
|
|
| temperature dial setting, check for proper | |
|
|
| location of capillary bulb in its spring holder. If | |
|
|
| above checks okay, replace | |
| Fuse, 10 Amp |
| Check, replace if necessary. | |
| Fuse holder |
| Check, replace if necessary. | |
| Control box | Check for voltage on both sides of the switch. | ||
|
|
| Terminals are normally closed. If open, reset | |
|
|
| and test oven for proper operation. If | |
|
|
| thermostat will not hold, and control box | |
|
|
| temperature is not exceeding 140° F (60° C) | |
|
|
| replace thermostat. |
|
| Main fan switch | With power off, Check continuity between | ||
|
|
| switch terminals. Replace as needed. | |
| Main fan motor |
| Check for opens, shorts or grounds. With | |
|
|
| power off, turn fan blade to check for locked | |
|
|
| rotor. |
|
| Capacitor |
| Check for shorts or grounds. | |
|
|
| WARNING: Capacitor has a stored charge, | |
|
|
| discharge before testing. | |
No control box cooling |
|
| Check for main fan operation. If not operating, | |
|
|
| refer to “Oven fan will not run”. | |
| Cooling fan |
| Line voltage should now be at the cooling fan. | |
|
|
| If voltage is present, check motor for shorts or | |
|
|
| opens. With power off, check for locked rotor. | |
No automatic control box | Incoming power supply | Check circuit breakers. Reset if required. Call | ||
cooling |
|
| power company if needed. | |
| Oven cavity | Terminals are normally closed. If open, reset | ||
| thermostat |
| and test oven for proper operation. If | |
|
|
| thermostat will not hold for maximum oven | |
|
|
| temperature, and oven is not exceeding | |
|
|
| temperature dial setting, check for proper | |
|
|
| location of capillary bulb in its spring holder. If | |
|
|
| above checks okay, replace | |
| Cooling fan thermostat | Check the cooling fan thermostat (thermostat | ||
|
|
| closes at 120° F and opens at 100° F). With the | |
|
|
| cooling fan thermostat preheated, check for | |
|
|
| continuity. If switch is open, replace thermostat. | |
| Cooling fan |
| Line voltage should now be at the cooling fan. | |
|
|
| If voltage is present, check motor for shorts or | |
|
|
| opens. With power off, check for locked rotor. | |
Control box cooling fan | Cooling fan thermostat | This normally open thermostat should close at | ||
continues to run |
|
| 120°F (48.9°C) and reopen at 100°F (37.8°C). | |
|
|
| Replace as needed. |
|
Impinger II – | 11 |