Lincoln 1100-000-A SERIES (SN 2038615 & BELOW) service manual Burner Alarm Replacement

Page 20

BURNER ALARM – REPLACEMENT

.

Shut off power at main breaker.

.

Remove control panel top and front cover.

.

Remove two wires from burner alarm and mark for reassembly.

.

Remove mounting ring from burner alarm and remove from control box.

.

Reassemble in reverse order and check system operation.

SPARK GENERATOR – REPLACEMENT

.

Shut off power at main breaker.

.

Remove control panel top and front panel.

.

Remove all wires from spark generator and mark for reassembly.

.

Remove two mounting screws and remove spark generator.

.

Reassemble in reverse order and check system operation.

MAIN BURNER ORIFICE – REPLACEMENT

.

Shut power at main breaker.

.

Shut off gas supply to oven.

.

Remove control panel top and front cover.

.

Remove burner manifold. (See “TEMPERATURE REGULATION VALVE”)

.

Remove main burner orifice from burner manifold.

.

Reassemble in reverse order and check system operation. Check all gas line fittings for leaks.

MERURY CONTACTOR – REPLACEMENT

.

Shut off power at main breaker.

.

Remove control panel top and front cover.

.

Disconnect all wires from mercury contactor and mark for reassembly.

.

Remove mounting screws and remove mercury contactor.

.

Reassemble in reverse order and check system operation.

AIR PRESSURE SWITCH – MAIN FAN - REPLACEMENT AND ADJUSTMENT

.

Shut off power at main breaker.

.

Remove control panel top and front cover.

.

Disconnect all wires and mark for reassembly.

.

Disconnect air switch tube from air pressure switch.

.

Remove mounting screws and remove air pressure switch.

.

Reassemble in reverse order and check system operation. Adjust air pressure switch as needed.

.

To adjust air pressure switch, turn adjusting screw fully counter clockwise. With heat on, turn adjusting screw

 

clockwise until heat shuts off. Turn adjusting screw ¼ turn counter clockwise and unit should heat.

AIR PRESSURE SWITCH – BURNER MOTOR – REPLACEMENT AND CALIBRATION

.

Shut off power at main breaker.

.

Remove control panel top and front cover.

.

Disconnect all wires and mark for reassembly.

.

Remove air tube from air pressure switch and remove air pressure switch from hanger.

.

Reassemble in reverse order and check system operation. Adjust air pressure switch as needed.

.

To adjust air pressure switch, remove cover over terminals to access adjustment screw. To increase

 

sensitivity, turn screw counter clockwise. Check for proper line voltage switching from N.C. to N.O. as the air

 

pressure switch closes.

HEATING ELEMENT – REPLACEMENT

.

Shut off power at main breaker.

.

Remove back cover.

.

Disconnect motor wires and heating element wires and mark for reassembly.

.

Remove oven back from oven.

20

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

Image 20
Contents Impinger Countertop Oven Power Supply Temperature ControlTemperature Display Control BOX Auto Cool DownHeat Circuit Schematic Diagram Model 1164-000-EA Refer to Proper Schematic for Identified Components Symptom Possible Cause EvaluationPage Page Page Page Troubleshooting Guide Electric Ovens Page Page Page MOTOR, Main FAN Replacement Main FAN ReplacementCAPACITOR, Motor Replacement ON/OFF Switch ReplacementFuse Holder Replacement THERMOSTAT, Control BOX HI-LIMIT ReplacementCooling FAN, Control BOX Replacement THERMOSTAT, Cooling FAN ReplacementElectronic Temperature Control Replacement Thermocouple ReplacementThermocouple Measurement Chart Information Electronic Temperature Control Calibration Temperature Control Potentiometer ReplacementHeat Light Replacement Ignition Control ReplacementIGNITER/SENSOR Assembly Replacement Bypass Orifice ReplacementTemperature Regulation Valve Replacement Burner Alarm Replacement Spark Generator ReplacementMain Burner Orifice Replacement Merury Contactor ReplacementConveyor Control Potentiometer Replacement Conveyor Control Board ReplacementCircuit Breaker Replacement Conveyor Drive Motor ReplacementHall Effect Sensor Replacement Temperature Display Transformer ReplacementTemperature Display Replacement Temperature Display CalibrationThis page intentionally left blank General View Impinger II Advantage Letter Part Number DescriptionPage Control BOX View Impinger II Advantage Page Model 1164-000-EA Page CONVEYOR/DOOR View Impinger II Advantage Page Oven Back View Page This page intentionally left blank This page intentionally left blank