Lincoln 1100-000-A SERIES (SN 2038615 & BELOW) service manual Heat Circuit

Page 3

SEQUENCE OF OPERATIONS

MODEL 1164-000-EA

400/230 VAC

50 HZ.

3 PHASE

POWER SUPPLY

Electrical power to be supplied to the oven by a four conductor service.

Brown conductor is Hot.

Black conductor is Hot.

Black conductor is Hot.

Green conductor is ground.

CONTROL BOX AUTO COOL DOWN

When the temperature in the control box reaches 120° F, ± 3° (48.9°C, ± 1.7°C), the cooling fan thermostat will switch power to the control box cooling fan. The thermostat will interrupt power to the cooling fan when the control

box temperature falls to 100° F, ± 3° (37.8°C, ± 1.7°C).

MAIN FAN CIRCUIT

Power is permanently supplied through the normally closed oven cavity hi-limit, through the 10A fuse, through the normally closed control box hi-limit thermostat, to the normally open main fan switch. Power is also supplied to the normally open cooling fan thermostat. Closing the main fan switch supplies 230 VAC to the main fan motor, the cooling fan motor, to the primary of the temperature display transformer and to the heat and conveyor circuits.

HEAT CIRCUIT

Closing the oven fan switch supplies 230VAC, through the normally open air pressure switch (closed by air pressure from the main fan) to the electronic temperature control. The 1K ohm temperature potentiometer is adjusted to desired temperature. The thermocouple will provide varying millivolts to the temperature control. The temperature control then supplies 230 VAC to the coil of the contactor at intermittent intervals to maintain the desired temperature. The heat lamp is energized with the contactor.

CONVEYOR DRIVE

Closing the oven fan switch supplies 230 VAC through the EMI filter to the motor control board. AC volts are converted to DC volts and are supplied to the conveyor motor at terminals A+ and A-. Adjustment of the speed control potentiometer will change resistance at terminals P1 and P2 varying the DC voltage to the motor. The speed of the conveyor motor will increase or decrease as the DC voltage from the board increases or decreases respectively.

NOTE: The conveyor control uses a sensor and magnet, mounted on the conveyor motor, that senses the motor

speed. Any change in motor load (± RPM) is detected by the sensor and the voltage to the motor is adjusted accordingly.

TEMPERATURE DISPLAY

Closing the main fan switch supplies 230 VAC to the primary of the temperature display transformer. The secondary of this transformer supplies 12 VAC to the temperature display. The thermocouple supplies DC millivolts to the temperature display. The display converts this millivolt reading to a temperature reading.

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

3

Image 3
Contents Impinger Countertop Oven Control BOX Auto Cool Down Power SupplyTemperature Control Temperature DisplayHeat Circuit Schematic Diagram Model 1164-000-EA Symptom Possible Cause Evaluation Refer to Proper Schematic for Identified ComponentsPage Page Page Page Troubleshooting Guide Electric Ovens Page Page Page ON/OFF Switch Replacement MOTOR, Main FAN ReplacementMain FAN Replacement CAPACITOR, Motor ReplacementTHERMOSTAT, Cooling FAN Replacement Fuse Holder ReplacementTHERMOSTAT, Control BOX HI-LIMIT Replacement Cooling FAN, Control BOX ReplacementThermocouple Replacement Thermocouple Measurement Chart InformationElectronic Temperature Control Replacement Ignition Control Replacement Electronic Temperature Control CalibrationTemperature Control Potentiometer Replacement Heat Light ReplacementBypass Orifice Replacement Temperature Regulation Valve ReplacementIGNITER/SENSOR Assembly Replacement Merury Contactor Replacement Burner Alarm ReplacementSpark Generator Replacement Main Burner Orifice ReplacementConveyor Drive Motor Replacement Conveyor Control Potentiometer ReplacementConveyor Control Board Replacement Circuit Breaker ReplacementTemperature Display Calibration Hall Effect Sensor ReplacementTemperature Display Transformer Replacement Temperature Display ReplacementThis page intentionally left blank Letter Part Number Description General View Impinger II AdvantagePage Control BOX View Impinger II Advantage Page Model 1164-000-EA Page CONVEYOR/DOOR View Impinger II Advantage Page Oven Back View Page This page intentionally left blank This page intentionally left blank