BYPASS ORIFICE – REPLACEMENT |
| |
. | Shut off power at main breaker. |
|
. | Shut off gas supply to oven. |
|
. | Remove control panel top and front cover. |
|
. | Remove pilot tube from bypass orifice and remove orifice. |
|
. | Reassemble in reverse order and check system operation. |
|
. | Check gas line fittings for leaks. |
|
TEMPERATURE REGULATION VALVE – REPLACEMENT |
| |
. | Shut off power at main breaker. |
|
. | Shut off gas supply to oven. |
|
. | Remove control panel top and front cover. |
|
. | Remove bypass tube from burner. |
|
. | Disconnect wires from temperature regulation valve and mark for reassembly. |
|
. | Remove four nuts from burner manifold and disconnect pipe union. |
|
. | Remove temperature regulation valve and piping from oven. |
|
. | Remove piping from valve and reassemble in reverse order and check system operation. Check all gas line |
|
| fittings for leaks. |
|
IGNITER/SENSOR ASSEMBLY – REPLACEMENT |
| |
. | Shut off power at main breaker. |
|
. | Shut off gas supply to oven. |
|
. | Remove control panel top and front cover. |
|
. Remove gas valve assembly.(see “GAS VALVE”) |
| |
. | Remove temperature regulation valve. (see “TEMPERATURE REGULATION VALVE”) |
|
. | Disconnect all wires from burner and mark for reassembly. |
|
. | Remove screws from burner tube and remove burner venturi. |
|
. | Remove two mounting screws and remove igniter/sensor assembly from burner venturi. |
|
. | Reassemble in reverse order and check system operation. Check all gas line fittings for leaks. |
|
Impinger II – | 19 |