Air pressure switch

Check air switch terminals for supply voltage to

 

 

terminals NO 2 and COM. If voltage is present

 

 

on one side only, check for air tube blockage or

 

 

misalignment. If these are okay, adjust switch

 

 

or replace if necessary.

 

Oven cavity hi-limit

Terminals are normally closed, opens at 660° F

 

thermostat

°

 

 

(350 C). If open, push in reset button and

 

 

retest. If thermostat will not hold for maximum

 

 

oven temperature, and oven is not exceeding

 

 

temperature dial setting, check for proper

 

 

location of capillary bulb in its spring holder. If

 

 

above checks are okay, replace hi-limit

 

 

thermostat.

 

Ignition control

Check for proper supply voltage to ignition

 

 

control. Check for proper line voltage to the

 

 

burner blower motor. This can be checked at

 

 

motor connecting plug terminals 2 and 5. If

 

 

voltage is present, proceed with next step, if

 

 

not, wait 30 seconds, push reset button and try

 

 

to restart. If this fails, check wires from

 

 

thermostat and burner blower motor to the

 

 

ignition control. If all above checks okay,

 

 

replace ignition control.

 

Burner blower motor

Check for supply voltage to motor. WITH

 

 

POWER OFF: Turn blower wheel to check for

 

 

locked rotor. If proper supply voltage is present

 

 

at motor connecting plug, terminals 2 and 5,

 

 

and motor does not run, replace motor.

 

Air pressure switch

Check for proper supply voltage switching from

 

(burner blower)

“NC” to “NO” on ignition control. Check for air

 

 

switch adjustment, air tube blockage or

 

 

misalignment. If these fail, replace air pressure

 

 

switch.

 

Spark generator

A pre-purge time of 30 to 60 seconds occurs

 

 

after blower motor starts. Check for supply

 

 

voltage at spark generator. If voltage is not

 

 

present, check reset button for the ignition

 

 

control. If voltage is still not present, replace

 

 

ignition control. If there is input voltage but

 

 

there is no output voltage, replace spark

 

 

generator.

 

Igniter/sensor assembly

Check this assembly for visible damage.

 

 

Replace as needed. If there is no visible

 

 

damage, check for supply voltage to

 

 

igniter/sensor assembly. If there is supply

 

 

voltage to igniter/sensor assembly, but there is

 

 

no spark, replace igniter/sensor assembly.

 

Gas valve

Gas valve should open when proper supply

 

 

voltage is present. If no voltage is present,

 

 

check the reset button on ignition control, and

 

 

all connections for tightness. If there is still no

 

 

voltage at gas valve, replace the ignition

 

 

control. If there is voltage present, check for

 

 

gas pressure at the gas pressure tap (located

 

 

in the gas piping just prior to the burner). If

 

 

there is no gas pressure, replace the gas valve.

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

7

Image 7
Contents Impinger Countertop Oven Control BOX Auto Cool Down Power SupplyTemperature Control Temperature DisplayHeat Circuit Schematic Diagram Model 1164-000-EA Symptom Possible Cause Evaluation Refer to Proper Schematic for Identified ComponentsPage Page Page Page Troubleshooting Guide Electric Ovens Page Page Page ON/OFF Switch Replacement MOTOR, Main FAN ReplacementMain FAN Replacement CAPACITOR, Motor ReplacementTHERMOSTAT, Cooling FAN Replacement Fuse Holder ReplacementTHERMOSTAT, Control BOX HI-LIMIT Replacement Cooling FAN, Control BOX ReplacementThermocouple Measurement Chart Information Thermocouple ReplacementElectronic Temperature Control Replacement Ignition Control Replacement Electronic Temperature Control CalibrationTemperature Control Potentiometer Replacement Heat Light ReplacementTemperature Regulation Valve Replacement Bypass Orifice ReplacementIGNITER/SENSOR Assembly Replacement Merury Contactor Replacement Burner Alarm ReplacementSpark Generator Replacement Main Burner Orifice ReplacementConveyor Drive Motor Replacement Conveyor Control Potentiometer ReplacementConveyor Control Board Replacement Circuit Breaker ReplacementTemperature Display Calibration Hall Effect Sensor ReplacementTemperature Display Transformer Replacement Temperature Display ReplacementThis page intentionally left blank Letter Part Number Description General View Impinger II AdvantagePage Control BOX View Impinger II Advantage Page Model 1164-000-EA Page CONVEYOR/DOOR View Impinger II Advantage Page Oven Back View Page This page intentionally left blank This page intentionally left blank