Lincoln 1100-000-A SERIES (SN 2038615 & BELOW) service manual Fuse Holder Replacement

Page 16

FUSE HOLDER – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Remove wires from fuse holder and mark for reassembly.

D.Remove mounting screws or mounting nut from fuse holder and remove fuse holder.

E.Reassemble in reverse order and check system operation.

THERMOSTAT, CONTROL BOX HI-LIMIT – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Remove wires from thermostat and mark for reassembly.

D.Remove mounting screws and remove thermostat.

E.Reassemble in reverse order and check system operation. NOTE: Push reset button on new thermostat.

COOLING FAN, CONTROL BOX – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Remove four screws from fan frame.

D.Disconnect cord and plug from fan and remove fan.

E.Reassemble in reverse order and check system operation.

THERMOSTAT, COOLING FAN – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Remove wires and mark for reassembly.

D.Remove mounting screws and remove thermostat.

E.Reassemble in reverse order and check system operation.

BURNER BLOWER MOTOR – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Unplug motor connector.

D.Remove three mounting screws at burner housing and remove motor.

E.Remove air shutter assembly from old motor and install on new motor.

F.Reassemble in reverse order and check system operation.

NOTE: Set air shutter at approximately ½ open and adjust to get a good blue flame in high flame operation.

THERMOSTAT, OVEN CAVITY HI-LIMIT – REPLACEMENT

A.Shut off power at main breaker.

B.Remove control panel top and front cover.

C.Remove conveyor and bottom finger assembly.

D.Remove capillary tube from mounting bracket in oven chamber and pull through tube into control box.

E.Remove wires from thermostat and mark for reassembly.

F.Remove mounting nut and remove thermostat.

G.Reassemble in reverse order and check system operation. Make sure capillary tube is mounted in the mounting bracket.

NOTE: Push reset button on new thermostat.

16

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

Image 16
Contents Impinger Countertop Oven Power Supply Temperature ControlTemperature Display Control BOX Auto Cool DownHeat Circuit Schematic Diagram Model 1164-000-EA Refer to Proper Schematic for Identified Components Symptom Possible Cause EvaluationPage Page Page Page Troubleshooting Guide Electric Ovens Page Page Page MOTOR, Main FAN Replacement Main FAN ReplacementCAPACITOR, Motor Replacement ON/OFF Switch ReplacementFuse Holder Replacement THERMOSTAT, Control BOX HI-LIMIT ReplacementCooling FAN, Control BOX Replacement THERMOSTAT, Cooling FAN ReplacementThermocouple Measurement Chart Information Thermocouple ReplacementElectronic Temperature Control Replacement Electronic Temperature Control Calibration Temperature Control Potentiometer ReplacementHeat Light Replacement Ignition Control ReplacementTemperature Regulation Valve Replacement Bypass Orifice ReplacementIGNITER/SENSOR Assembly Replacement Burner Alarm Replacement Spark Generator ReplacementMain Burner Orifice Replacement Merury Contactor ReplacementConveyor Control Potentiometer Replacement Conveyor Control Board ReplacementCircuit Breaker Replacement Conveyor Drive Motor ReplacementHall Effect Sensor Replacement Temperature Display Transformer ReplacementTemperature Display Replacement Temperature Display CalibrationThis page intentionally left blank General View Impinger II Advantage Letter Part Number DescriptionPage Control BOX View Impinger II Advantage Page Model 1164-000-EA Page CONVEYOR/DOOR View Impinger II Advantage Page Oven Back View Page This page intentionally left blank This page intentionally left blank