Lincoln 1100-000-A SERIES (SN 2038615 & BELOW) service manual Symptom Possible Cause Evaluation

Page 6

 

TROUBLESHOOTING GUIDE

 

 

GAS OVENS

 

 

 

1154-000-EA

NAT. GAS

230VAC

50 HZ.

1 PHASE

1155-000-EA

LP GAS

230VAC

50 HZ.

1 PHASE

REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS

 

 

 

 

 

SYMPTOM

POSSIBLE CAUSE

 

EVALUATION

 

Oven fan will not run

Incoming power supply

 

Check breakers, reset if required. Check power

 

 

 

plug to be sure it is firmly in receptacle.

 

 

 

Measure incoming power, call power co. if

 

 

 

needed

 

 

Fuse, 10A

 

Check, replace if necessary.

 

Fuse holder

 

Check, replace if necessary.

 

Hi-limit thermostat, control

Check for voltage on both sides of the switch.

 

box

 

Terminals are normally closed. If open, reset

 

 

 

and test oven for proper operation. If

 

 

 

thermostat will not hold, and control box

 

 

 

temperature is not exceeding 140° F (60° C)

 

 

 

replace thermostat.

 

 

Main fan switch

 

With power off, Check continuity between

 

 

 

switch terminals. Replace as needed.

 

Main fan motor

 

Check for opens, shorts or grounds. With

 

 

 

power off, turn fan blade to check for locked

 

 

 

rotor.

 

 

 

Capacitor

 

Check for shorts or grounds.

 

 

 

WARNING: Capacitor has a stored charge,

 

 

 

discharge before testing.

No control box cooling

Incoming power supply

 

Check main circuit breakers, reset if required.

 

 

 

Call power co. if needed.

 

Main fan switch

 

With power off, Check continuity between

 

 

 

switch terminals. Replace as needed.

 

Cooling fan

 

Line voltage should now be at the cooling fan.

 

 

 

If voltage is present, check motor for shorts or

 

 

 

opens. With power off, check for locked rotor.

No automatic control box

Incoming power supply

 

Check main circuit breakers, reset if required.

cooling

 

 

Call power co. if needed.

 

Cooling fan thermostat

 

Check the cooling fan thermostat (thermostat

 

 

 

closes at 120° F and opens at 100° F). With the

 

 

 

cooling fan thermostat preheated, check for

 

 

 

continuity. If switch is open, replace thermostat.

Oven will not heat

Gas supply

 

Check for adequate gas supply and be sure

 

 

 

that manual gas shut off valve is open. Also

 

 

 

check flexible gas line connection.

 

Main fan

 

If not operating, refer to “Main fan will not run”

 

Gas pressure switch

 

This switch is located inside the gas valve and

 

 

 

should close when gas pressure is present.

 

 

 

WITH POWER OFF: Remove 3 prong plug (on

 

 

 

gas valve) and measure continuity between

 

 

 

terminals 2 and 3. If no continuity, check the

 

 

 

following: Proper gas pressure supply to gas

 

 

 

valve as marked on the oven specification

 

 

 

plate. Check for proper adjustment of gas

 

 

 

pressure switch, 10 for Nat. gas, 27 for LP gas

 

 

 

or 4.5 for town gas. Check the filter in gas

 

 

 

valve for blockage or damage. If above checks

 

 

 

are okay, but pressure switch is still not closed,

 

 

 

replace gas valve.

 

6

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

Image 6
Contents Impinger Countertop Oven Temperature Display Power SupplyTemperature Control Control BOX Auto Cool DownHeat Circuit Schematic Diagram Model 1164-000-EA Refer to Proper Schematic for Identified Components Symptom Possible Cause EvaluationPage Page Page Page Troubleshooting Guide Electric Ovens Page Page Page CAPACITOR, Motor Replacement MOTOR, Main FAN ReplacementMain FAN Replacement ON/OFF Switch ReplacementCooling FAN, Control BOX Replacement Fuse Holder ReplacementTHERMOSTAT, Control BOX HI-LIMIT Replacement THERMOSTAT, Cooling FAN ReplacementThermocouple Replacement Thermocouple Measurement Chart InformationElectronic Temperature Control Replacement Heat Light Replacement Electronic Temperature Control CalibrationTemperature Control Potentiometer Replacement Ignition Control ReplacementBypass Orifice Replacement Temperature Regulation Valve ReplacementIGNITER/SENSOR Assembly Replacement Main Burner Orifice Replacement Burner Alarm ReplacementSpark Generator Replacement Merury Contactor ReplacementCircuit Breaker Replacement Conveyor Control Potentiometer ReplacementConveyor Control Board Replacement Conveyor Drive Motor ReplacementTemperature Display Replacement Hall Effect Sensor ReplacementTemperature Display Transformer Replacement Temperature Display CalibrationThis page intentionally left blank General View Impinger II Advantage Letter Part Number DescriptionPage Control BOX View Impinger II Advantage Page Model 1164-000-EA Page CONVEYOR/DOOR View Impinger II Advantage Page Oven Back View Page This page intentionally left blank This page intentionally left blank