Lincoln 1100-000-A SERIES (SN 2038615 & BELOW) Conveyor Control Potentiometer Replacement

Page 21

. Remove fan shroud.

. Remove heating element(s) from oven back.

. Reassemble in reverse order and check system operation. Apply anti-seize compound to all mounting bolts on elements and back bolts.

NOTE: Be sure all wiring connections are tight. Loose connections at on the elements may cause the terminals to burn off and damage the elements or wiring.

CONVEYOR CONTROL POTENTIOMETER – REPLACEMENT

. Shut off power at main breaker.

. Remove control panel top and front cover.

. Loosen two allen screws and remove knob by sliding knob off of shaft.

. Remove mounting nut from potentiometer shaft and remove potentiometer.

. Disconnect potentiometer wires and mark for reassembly.

. Reassemble in reverse order and check system operation.

CONVEYOR CONTROL BOARD – REPLACEMENT

. Shut off power at main breaker.

. Remove control panel top and front cover.

. Disconnect wiring from conveyor control board and mark for reassembly.

. Remove conveyor control board from its mounting bracket.

. Reassemble in reverse order. Calibrate new conveyor control board and check system operation. NOTE: Be sure that jumper (on conveyor control) is set to the proper input voltage (120/240) position.

CONVEYOR CONTROL BOARD – CALIBRATION

. Connect digital voltmeter to the hall effect sensor. Black meter lead connected to black hall effect sensor lead, red meter lead to white hall effect sensor lead.

. Turn conveyor control knob fully counter clockwise. Loosen knob and align with calibration mark and tighten knob.

. Set conveyor control knob to the 1-minute setting. Adjust “MAX” pot on conveyor control to 327.5Hz.

. Set conveyor control knob to the 30-minute setting. Adjust “MIN” pot on conveyor control to 10.9 Hz. Recheck

at 1 minute and 30 minute settings until proper readings are achieved. Seal pots with glyptol or nail polish.

CIRCUIT BREAKER – REPLACEMENT

.

Shut off power at main breaker.

 

.

Remove control panel top and front cover.

 

.

Disconnect two wires from circuit breaker and mark for reassembly.

 

.

Remove mounting nut from circuit breaker and remove circuit breaker.

 

.

Reassemble in reverse order and check system operation.

 

 

NOTE: Be sure to reset circuit breaker before operation.

 

CONVEYOR DRIVE MOTOR – REPLACEMENT

 

.

Shut off power at main breaker.

 

.

Remove control panel top and front cover.

 

.

Remove conveyor.

 

.

Disconnect wiring from motor and mark for reassembly.

 

.

Remove coupling from motor drive shaft.

 

.

Remove four mounting screws and remove conveyor motor and mounting bracket.

 

.

Remove mounting bracket from conveyor motor.

 

.

Reassemble in reverse order and check system operation.

 

REVERSING CONVEYOR DIRECTION

 

.

Shut off power at main breaker.

 

.

Remove control panel top and front cover.

 

.

Reverse wires fastened to terminals A+ and A- on conveyor control board. (See schematic diagram for wire

 

 

numbers.)

 

.

Reassemble in reverse order and check system operation.

 

Impinger II – 1100-000-A Series (SN 2038615 & Below) Service Manual –Int’l

21

Image 21
Contents Impinger Countertop Oven Temperature Control Power SupplyTemperature Display Control BOX Auto Cool DownHeat Circuit Schematic Diagram Model 1164-000-EA Symptom Possible Cause Evaluation Refer to Proper Schematic for Identified ComponentsPage Page Page Page Troubleshooting Guide Electric Ovens Page Page Page Main FAN Replacement MOTOR, Main FAN ReplacementCAPACITOR, Motor Replacement ON/OFF Switch ReplacementTHERMOSTAT, Control BOX HI-LIMIT Replacement Fuse Holder ReplacementCooling FAN, Control BOX Replacement THERMOSTAT, Cooling FAN ReplacementThermocouple Replacement Thermocouple Measurement Chart InformationElectronic Temperature Control Replacement Temperature Control Potentiometer Replacement Electronic Temperature Control CalibrationHeat Light Replacement Ignition Control ReplacementBypass Orifice Replacement Temperature Regulation Valve ReplacementIGNITER/SENSOR Assembly Replacement Spark Generator Replacement Burner Alarm ReplacementMain Burner Orifice Replacement Merury Contactor ReplacementConveyor Control Board Replacement Conveyor Control Potentiometer ReplacementCircuit Breaker Replacement Conveyor Drive Motor ReplacementTemperature Display Transformer Replacement Hall Effect Sensor ReplacementTemperature Display Replacement Temperature Display CalibrationThis page intentionally left blank Letter Part Number Description General View Impinger II AdvantagePage Control BOX View Impinger II Advantage Page Model 1164-000-EA Page CONVEYOR/DOOR View Impinger II Advantage Page Oven Back View Page This page intentionally left blank This page intentionally left blank