Multiquip 8FP Series manual MAINTENANCE, Repair and Storage

Page 13

SAFETY PRECAUTIONS

skill/common sense may dictate that a different type of machine (with characteristics of higher purchase cost, being mounted to a carrier vehicle, with greater horsepower and less mobility), method and/or process be utilized to properly complete the job with the degree of efficiency and safety required. Contact the Customer Service Department for specific information regarding suitable job applications, job sites surface conditions and operator experience/skill/common sense recommendations for this FLOOR PLANER BEFORE utilization. There is no charge for this service.

MAINTENANCE, REPAIR AND STORAGE.

1)Use only genuine, approved replacement parts and accessories for maintenance and repair. Use of parts and accessories manufactured by others can result in property damage and/or personal injury.

2)Follow the Service instructions as outlined in the appropriate section of this manual.

3)Always stop the engine or electric motor and disconnect the spark plug wire or power source cable BEFORE checking or working on the FLOOR PLANER.

4)Always properly maintain the FLOOR PLANER. Frequently check all fasteners and individual parts. Built in safety features are effective only if they are maintained in good working condition. Replace any questionable part or assembly with a genuine, factory approved, replacement part. Do not forsake proper maintenance for the price of a few replacement parts. Proper maintenance does not cost...it actually pays dividends. Do not attempt any maintenance repair work not described in this manual. Have such work performed at your dealer's service facility.

5)A worn or damaged engine muffler is a fire hazard and may cause loss of hearing. Check to see that the muffler is in good condition. If the muffler is equipped with a spark arresting device, determine that it is in proper working condition at regular service intervals. Replace the spark arresting device with an approved replacement if there is any question of it integrity. It is the responsibility of the owner(s) and/or operator(s) to provide for and properly maintain a USDA approved, spark arresting muffler in an operating area specified by law. Check with appropriate governing agencies for more specific information. The FLOOR PLANER must not be operated if the muffler is faulty or has been removed. Contact with a hot engine muffler can cause property damage and/or personal injury.

6)Do not operate the FLOOR PLANER without the use of factory approved V-belt and diamond blade guards that are maintained in proper structural condition.

7)Maintain all safety and operation decals in proper condition. If any decal becomes damaged and/or unreadable, replace with genuine, factory approved, replacement parts only.

8)The Floor Planer utilizes self locking hexagon head nuts to minimize the effects of vibration. Replace all self locking hardware with genuine, factory approved, replacement parts only.

9)Consult the material supplied by the engine or electric motor manufacturer for specific information relative to proper operational, lubrication and storage requirements.

8FP FLOOR PLANER SERIES

OPERATION AND PARTS MANUAL REV #2 (05/28/09)

PAGE 13

 

 

 

Image 13
Contents Electric and Gasoline Floor Planers Model 8FP Series Page Table of Contents Table of Contents Page Parts Ordering Procedures Page Page Operator Instructional Data Sheet Safety Precautions Safety Precautions Operation MAINTENANCE, Repair and Storage Application All Models Removing the Floor Planer from the PalletFilling the 8FP/G Series Engine Fuel Tank Flail Design and Application Theory of OperationBeam Flail Star FlailMilling Flail Pentagonal FlailFunction of Spacer Washers Spacer WashersProblems encountered by uneven component wear Flail Drum Design and Application General Notes Regarding Flail Drums Installing Flails on the TWO Section DrumNormal installation procedure for milling flails Installing a Loaded Drum on the Driveshaft General Notes Regarding the Installation of FlailsTransporting the Floor Planer Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Operating the Floor Planer on the JOB Site Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Stopping the 8FP/G Series Gasoline Powered Floor Planer Stopping the 8FP/E Series Electrically Powered Floor PlanerPreventative Maintenance Check LIST. Application All Models Observe all applicable safety precautions for the solvent Application As Specified Installing a Replacement V-BELT or PulleyAssembly INSTRUCTIONS/OPERATIONS Application All Models Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Assembly INSTRUCTIONS/OPERATIONS Aligning the Caster Wheels Checking Driveshaft RUN OUT Page Engine Service MAINTENANCE/SERVICEApplication 8FP/G Series Floor Planer Troubleshooting Accelerated Bearing Wear AND/OR Failure Accelerated V-BELT WearUneven Cutting Action Storage StorageGeneral FrameExplanation of Code in Remarks Column Qty Description Suggested Spare PartsMain Frame Assy Main Frame AssemblyFRAME, Main Main Frame Assy Part Name QTYTUBE, Vacuum Axle MountDriveshaft Assy Driveshaft AssemblyRING, Retaining External Driveshaft Assy Part Name QTY. RemarksSHEAVE, Driveshaft KEY, SpecialRear Frame Assy Rear Frame AssemblyPIN, Roll 3/16 X 1 Plated Rear Frame Assy Part Name QTY RemarksBUSHING, Connex SHAFT, Hinge PlatedOperator Handle Assy Gasoline Operator Handle Assembly GasolineBARREL, Adjusting BOOT, RubberSWITCH, SHUT-OFF TAP, 22-18 Guage WireGasoline Engine Assy Gasoline Engine AssemblyFRAME, Main GX160KQXC9 ENGINE, Honda 5.5HP Part Name QTY. RemarksDrive Pulley BUSHING, Center HUBOperator Handle Assy Operator Handle Assembly ElectricAdjusting Tube Switch Mount Height Adjustment ScrewHOUSING, Switch SWITCH, ON/OFFElectric Motor Assy Electric Motor AssemblyMotor Plate MOTOR, Electric 5HPRELIEF, Strain NUT, BulklheadONE Section Drum Assy ONE Section Drum AssemblyFlail Drum END CAP ONE Section Drum Assy Part NameFlail Drum ROD WASHER, Lock 1/4TWO Section Drum Assy TWO Section Drum AssemblyFlail Drum 2 Section TWO Section Drum Assy Part NameFlails & Spacer Washers Assy FLAILS, Spacers and Washers AssemblyStar Flail FLAILS, Spacers and Washers Assy Part Name QTYSpacer Washer Beam FlailDecals Decal Warning Flails Decals Part Name QTY RemarksDecal Depth Control Decal MQ LogoEffective February 22 Page HERE’S HOW to GET Help