Schneider Electric Class 615 dimensions Protection

Page 12

Compact® NSF and NSJ 150 to 600 A Circuit Breakers

Section 4—Trip Units

Electronic Trip Unit STR23SP and STR23SP-OSN (Oversized Neutral)

06153065

7

1

6

3

 

 

 

STR 23 SP

alarm

90 %Ir

 

 

 

 

105

Io = sensor

long time

short time

.8

.9

Ir

.9

.93

Im

5

6

.7

1

.88

 

.95

4

 

7

.63

 

.85

 

.98

3

 

9

.5

 

.8

 

1

2

 

 

 

 

 

x In

 

x Io

 

 

x Ir

t

1

2

3

4

+ -

test

Ir Im

5

 

0

Ir Im

I

Protection

Long-time (LT) overload protection, adjustable threshold, based on the actual rms current

 

Adjustable threshold (1) using six lo base settings (0.5–1) and fine adjustment Ir with eight settings ranging from (0.8–1)

Non-adjustable tripping time (2)

Short-time (ST) short-circuit protection

Adjustable threshold Im (3)

Fixed time delay (4)

Instantaneous (I) short-circuit protection, fixed threshold (5)

Neutral protection available on standard four-pole circuit breakers; protection level controlled using three-position switch

4P 3D: no protection

4P 3D + N/2: neutral protection at 0.5 Ir

4P 4D: neutral protection at Ir

Neutral protection for STR23SP-OSN (oversized neutral) available on four-pole circuit breakers equipped with oversized neutral protection; protection level controlled using three-position switch

NSJ250/400N:

NSJ400/600N:

4P

3D: no protection

4P

3D: no protection

4P

3D + N/2: neutral protection at 0.8 x Ir

4P

3D + N/2: neutral protection at 0.75 x Ir

4P

4D: neutral protection at 1.6 x Ir

4P

4D: neutral protection at 1.5 x Ir

12

© 1995–2003 Schneider Electric All Rights Reserved

Image 12
Contents Compact NSF and NSJ Page Table of Contents Compact Circuit Breaker Line Rated Current aCompact Interrupting Rating at 480General Characteristics Compliance with StandardsInstallation Class Switchboards Longer Service Life of Electrical InstallationsCircuit Breakers Ratings and Interrupting RatingsUL 489 Listed Ratings IEC 947-2 and EN 60947-2 RatingsCompact Circuit Breakers NSJ400 NSJ600 Rated Voltage Ultimate Breaking Capacity IcuKA rms Trip Units Trip Units for Compact NSF150 and NSF250 Circuit BreakersProtection Against overload 1 with a fixed thermal protectionTrip Units for Compact NSJ400 and NSJ600 Circuit Breakers Trip UnitsSTR53UP Protection Unit or other accessories Setting ExampleWith trip unit STR23SP where Io = 0.5 and Ir = 0.8? IndicationsOverload Indications %Ir Fault Indications Electronic Trip Unit STR53UPProtection Self-monitoringOptions for Electronic TripElectronic Trip Unit Test Kits Mini Test Kit and Hand-held Test KitPortable Test Kit Full-function Switches UL 1087 Listed RatingsIEC 947-3 Ratings NSF150A NSF250AShort-circuit Withstand Current NSJ400A NSJ600AMotor Circuit Protectors UL 489 Recognized ComponentNSF150HC NSF250HC NSJ400HC NSJ600HC Mounting Configurations Fixed MountingConnections PLUG-IN MountingParts of a Plug-in Configuration Drawout MountingMounting Horizontally or verticallyAccessories Connection of AuxiliariesConnections Front ConnectionConnection to Cables Copper or Aluminum CableRear Connection Connection to BarsPlug-in Mounting Drawout Compact Circuit Breake r NSF150/250 NSJ400/600Accessories LocationPlug-in and Drawout Mounting Automatic Secondary Disconnecting Blocks Auxiliary and Alarm Switches Electrical Ratings UL 489 and CSA C22.2 No .1 RatingsIEC 947 Ratings Shunt Trip and Undervoltage Trip Undervoltage tripShunt trip MX OperationMotor Operator ApplicationsAutomatic Manual OperationAccessories for CharacteristicsNSJ400/600 Keylock for locking in OFF positionRotary Operating Handles Directly MountedDoor Mounted Cable Operating Handle Flange-mountedHandle Cable OperatingLocking Systems Locking In the Off PositionInterlocking Accessories Interlocking of Circuit Breakers with Toggle ControlInterlocking of Circuit Breakers With Rotary HandlesUse Toggle Boot FRONT-PANEL EscutcheonsFor Fixed or Plug- in Mounting Front-panel Escutcheons for ToggleSealing Accessory For Drawout MountingIdentification Toggle CollarsDimensions DimensionsFixed Mounted Mounting on BackplateFront-panel Cutouts With Toggle Boot With Escutcheon C20 C21H53 H54 R12 R13Dimensions Plug-in On Base PLUG-IN and Drawout MountingDrawout On Chassis See Fixed-mounted Installation Mounting Through a Backplate Plug-in BaseOn Rails Plug-in Base or Chassis Front-panel Cutouts Plug-in MountingC11 C17 G10 G11 G12 G13 G20 G21 H16 H17 H18 H19 K11 K12 K13 K20 K21L10 P12 P44 Dimension Table Motor OperatorsFront-panel Cutouts C22 C23 H20 H21 H22 H23 L11 L12 P32 P33 P45 R14CABLE-OPERATING Handles Compact NSFCompact NSJ Dimensions ROTARY-OPERATING HandlesFront-panel Cutout Drawout Mounting C11 C17 C22 C23 G36 G37 G38 G39 H10 H20 H23 H24 H25 H26 K14 K15 L11 L12 L13 L14 L15 P34P35 P36 P37 P38 P40 P42 P43 P44 R14 R15 ØT6 ØT7Front Accessories Extended Escutcheons For ToggleFront-panel Escutcheons Interlocking Systems L16 L17 R19Connection Dimensions Plug-in or Drawout Mounting G33 G35 P22 P23Wiring Diagrams Manually-operated Circuit BreakerMotor-operated Circuit Breaker OFF Supplementary Technical Information Trip Units for Compact NSF150-NSF250 Circuit BreakersTM50DP TM90DP Effect of High Temperatures Example45 C 50 C 55 C 60 C 65 C 70 C Trip Units for Compact NSJ400-NSJ600 Circuit Breakers STR53UPReflex Tripping KA RMSLET-THROUGH Curves AT 480 Maximum Peak Let-through Current AmperesMaximum Let- through I2t Amperes2 Seconds LET-THROUGH Curves AT 600 SecondsCURRENT-LIMITING Curves AT 380/415 Maximum * LetCURRENT-LIMITING Curves AT 690 UL 489 Test Procedure Standard SpecificationsTemperature CalibrationOverload EnduranceAccessories DielectricOptional Tests Tests OnIEC 947-2 Test Procedure Two Categories of Devices Breaking CapacityIsolation FunctionTest Sequences Sequence Category of Devices TestsRoutine and Maintenance Guidelines Insulation Resistance Tests Page Replaces 0615CT9901 dated 03/1999