Schneider Electric Class 615 Front-panel Cutouts With Toggle Boot With Escutcheon, C20 C21, ØT4

Page 42

Compact® NSF and NSJ 150 to 600 A Circuit Breakers

Section 10—Dimensions

Front-panel Cutouts

With Toggle Boot

With Escutcheon

06153135

06153136

 

X C21

 

C20

Y

R12

R13

Front Accessories: See Page 39

Z

 

06153137

X

C7

X

 

C6

Y

R6

R7

P6

Dimensions: in. / mm

 

 

C

C1

C2

C3

C6

C7

C20

C21

G

G1

G4

 

 

 

 

 

 

 

 

 

 

 

 

 

NSF150/250N/H/L

Inch

1.14

2.99

2.12

4.25

1.69

4.09

1.33

3.38

2.46

4.92

2.75

 

 

 

 

 

 

 

 

 

 

 

 

mm

29

76

54

108

43

104

34

86

62,5

125

70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSJ400/600N/H/L

Inch

1.63

4.56

3.64

7.24

2.08

5.74

1.83

4.96

3.93

7.87

4.46

 

 

 

 

 

 

 

 

 

 

 

 

mm

41.5

116

92.5

184

53

146

46.5

126

100

200

113.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G5

H

H1

H2

H3

H53

H54

K

K1

L

L1

 

 

 

 

 

 

 

 

 

 

 

 

 

NSF150/250N/H/L

Inch

5.51

3.16

6.33

3.70

7.40

3.74

7.48

0.68

1.37

2.06

4.13

 

 

 

 

 

 

 

 

 

 

 

 

mm

140

80.5

161

94

188

95

190

17.5

35

52.5

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSJ400/600N/H/L

Inch

8.93

5.01

10.03

5.61

11.22

6.69

13.38

0.88

1.77

2.75

5.51

 

 

 

 

 

 

 

 

 

 

 

 

mm

227

127.5

255

142.5

285

170

340

22.5

45

70

140

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L2

P1

P2

P4

P5

P6

R

R1

R2

R4

R6

 

 

 

 

 

 

 

 

 

 

 

 

 

NSF150/250N/H/L

Inch

5.51

3.18

3.38

4.37(*)

3.26

3.46

0.57

1.14

2.12

4.25

1.14

 

 

 

 

 

 

 

 

 

 

 

 

mm

140

81

86

111(*)

83

88

14.5

29

54

108

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NSJ400/600N/H/L

Inch

7.28

3.75

4.33

6.61

4.21

4.40

1.24

2.48

2.81

5.62

1.83

 

 

 

 

 

 

 

 

 

 

 

 

mm

185

95.5

110

168

107

112

31.5

63

71.5

143

46.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R7

R12

R13

ØT

ØT4

U**

 

 

 

 

 

 

 

 

 

 

NSF150/250N/H/L

Inch

2.28

1.69

3.38

0.23

0.86

- 1.25

 

 

 

 

 

 

 

 

 

mm

58

43

86

6

22

- 32

 

 

 

 

 

 

 

 

 

 

 

 

NSJ400/600N/H/L

Inch

3.66

2.48

4.96

0.23

1.25

- 1.25

 

 

 

 

 

 

 

 

 

mm

93

63

126

6

32

- 32

 

 

 

 

 

 

 

 

 

 

 

 

* P4 = 4.96 in./126mm for Compact® NSF250N/H/L Circuit Breaker

** U 0.78 in./20mm When Using Secondary Disconnecting Blocks (Compact® NSF150 and NSF250 Circuit Breakers)

NOTE: Door cutouts require a minimum distance between the center of the circuit breaker and the door hinge point Δ 3.93 in./100 mm + (h x 5).

06153138

h

Δ

42

© 1995–2003 Schneider Electric All Rights Reserved

Image 42
Contents Compact NSF and NSJ Page Table of Contents Compact Compact Circuit Breaker LineRated Current a Interrupting Rating at 480General Characteristics Compliance with StandardsInstallation Class Switchboards Longer Service Life of Electrical InstallationsUL 489 Listed Ratings Circuit BreakersRatings and Interrupting Ratings IEC 947-2 and EN 60947-2 RatingsCompact Circuit Breakers NSJ400 NSJ600 Rated Voltage Ultimate Breaking Capacity IcuKA rms Protection Trip UnitsTrip Units for Compact NSF150 and NSF250 Circuit Breakers Against overload 1 with a fixed thermal protectionTrip Units for Compact NSJ400 and NSJ600 Circuit Breakers Trip UnitsSTR53UP Protection With trip unit STR23SP where Io = 0.5 and Ir = 0.8? Unit or other accessoriesSetting Example IndicationsProtection Overload Indications %Ir Fault IndicationsElectronic Trip Unit STR53UP Self-monitoringOptions for Electronic TripElectronic Trip Unit Test Kits Mini Test Kit and Hand-held Test KitPortable Test Kit Full-function IEC 947-3 Ratings SwitchesUL 1087 Listed Ratings NSF150A NSF250AShort-circuit Withstand Current NSJ400A NSJ600AMotor Circuit Protectors UL 489 Recognized ComponentNSF150HC NSF250HC NSJ400HC NSJ600HC Connections Mounting ConfigurationsFixed Mounting PLUG-IN MountingMounting Parts of a Plug-in ConfigurationDrawout Mounting Horizontally or verticallyAccessories Connection of AuxiliariesConnection to Cables ConnectionsFront Connection Copper or Aluminum CablePlug-in Mounting Drawout Rear ConnectionConnection to Bars Compact Circuit Breake r NSF150/250 NSJ400/600Accessories LocationPlug-in and Drawout Mounting Automatic Secondary Disconnecting Blocks Auxiliary and Alarm Switches Electrical Ratings UL 489 and CSA C22.2 No .1 RatingsIEC 947 Ratings Shunt trip MX Shunt Trip and Undervoltage TripUndervoltage trip OperationAutomatic Motor OperatorApplications Manual OperationNSJ400/600 Accessories forCharacteristics Keylock for locking in OFF positionRotary Operating Handles Directly MountedDoor Mounted Handle Cable Cable Operating HandleFlange-mounted OperatingLocking Systems Locking In the Off PositionInterlocking of Circuit Breakers Interlocking AccessoriesInterlocking of Circuit Breakers with Toggle Control With Rotary HandlesUse For Fixed or Plug- in Mounting Toggle BootFRONT-PANEL Escutcheons Front-panel Escutcheons for ToggleIdentification Sealing AccessoryFor Drawout Mounting Toggle CollarsFixed Mounted DimensionsDimensions Mounting on BackplateH53 H54 Front-panel Cutouts With Toggle Boot With EscutcheonC20 C21 R12 R13Dimensions Plug-in On Base PLUG-IN and Drawout MountingDrawout On Chassis On Rails Plug-in Base or Chassis See Fixed-mounted InstallationMounting Through a Backplate Plug-in Base Front-panel Cutouts Plug-in MountingC11 C17 G10 G11 G12 G13 G20 G21 H16 H17 H18 H19 K11 K12 K13 K20 K21L10 P12 P44 Front-panel Cutouts Dimension TableMotor Operators C22 C23 H20 H21 H22 H23 L11 L12 P32 P33 P45 R14CABLE-OPERATING Handles Compact NSFCompact NSJ Dimensions ROTARY-OPERATING HandlesFront-panel Cutout Drawout Mounting P35 P36 P37 P38 P40 P42 P43 P44 R14 R15 C11 C17 C22 C23 G36 G37 G38 G39 H10 H20 H23 H24 H25H26 K14 K15 L11 L12 L13 L14 L15 P34 ØT6 ØT7Front Accessories Extended Escutcheons For ToggleFront-panel Escutcheons Interlocking Systems L16 L17 R19Connection Dimensions Plug-in or Drawout Mounting G33 G35 P22 P23Wiring Diagrams Manually-operated Circuit BreakerMotor-operated Circuit Breaker OFF Supplementary Technical Information Trip Units for Compact NSF150-NSF250 Circuit BreakersTM50DP TM90DP Effect of High Temperatures Example45 C 50 C 55 C 60 C 65 C 70 C Trip Units for Compact NSJ400-NSJ600 Circuit Breakers STR53UPReflex Tripping KA RMSLET-THROUGH Curves AT 480 Maximum Peak Let-through Current AmperesMaximum Let- through I2t Amperes2 Seconds LET-THROUGH Curves AT 600 SecondsCURRENT-LIMITING Curves AT 380/415 Maximum * LetCURRENT-LIMITING Curves AT 690 Temperature UL 489 Test ProcedureStandard Specifications CalibrationOverload EnduranceOptional Tests AccessoriesDielectric Tests OnIEC 947-2 Test Procedure Two Categories of Devices Breaking CapacityIsolation FunctionTest Sequences Sequence Category of Devices TestsRoutine and Maintenance Guidelines Insulation Resistance Tests Page Replaces 0615CT9901 dated 03/1999