FUNCTIONAL DESCRIPTION

GROUNDING

 

4

3

5

 

2

 

 

6

 

 

1.

Depth gauge

1

 

2.

Side handle

 

3.

Nameplate

 

 

 

7

4.

Trigger

 

5.

Handle

 

 

8

 

6.

Forward/Reverse switch

9

 

 

(on other side of tool)

 

7.

Hammer/Drill shift knob

 

 

8.

Chuck collar

 

 

9.

Dust shield

 

 

10.

Bit (not included)

10

Symbology

WARNING

Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electri- cian if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is damaged. If damaged, have it repaired by a MILWAUKEE service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.

Grounded Tools:

Tools with Three Prong Plugs

Tools marked “Grounding Required” have a three wire cord and three prong grounding plug. The plug must be connected to a prop- erly grounded outlet (See Figure A). If the tool should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user, reducing the risk of electric shock.

The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire con- nected to the tool's grounding system and must never be attached to an electrically “live” terminal.

Your tool must be plugged into an appropri- ate outlet, properly installed and grounded in accordance with all codes and ordinances. The plug and outlet should look like those in Figure A.

Double Insulated Tools:

Tools with Two Prong Plugs

Tools marked “Double Insulated” do not require grounding. They have a special double insulation system which satisfies OSHA requirements and complies with the applicable standards of Underwriters Laboratories, Inc., the Canadian Standard Association and the National Electrical Code. Double Insulated tools may be used in either of the 120 volt outlets shown in Figures B and C.

 

Double Insulated

 

 

 

 

Volts Alternating Current

 

 

 

 

Amps

 

 

 

 

No Load Revolutions per

 

Minute (RPM)

BPM

Blows per Minute

 

 

 

 

Underwriters Laboratories, Inc.

 

 

 

 

Canadian Standards

 

Association

 

Mexican Approvals Marking

 

 

 

 

4

 

Fig. A

Fig. B

Fig. C

Specifications

 

 

 

 

 

Drill Only

Rotary Hammer

 

 

 

 

 

(steel or wood)

(concrete)

 

 

 

 

 

 

 

 

 

 

 

 

 

Carbide-Tipped

Thin Wall

Catalog

Volts

 

No Load

No Load

Twist

 

Blows/

Percussion

Percussion

Number

AC

Amps

RPM

Minute

Drill Bits

Bits

Core Bits

5366-21

120

7.2

0 - 1100

0 - 5000

1/2"

5/32" - 7/8"

2"

5368-21

120

7.2

0 - 1100

0 - 5000

1/2"

5/32" - 7/8"

2"

5368-22

120

7.2

0 - 1100

0 - 5000

1/2"

5/32" - 7/8"

2"

5

Image 3
Contents 5366-21 5368-21 5368-22 Electrical Safety Personal Safety Power Tool USE and CareSpecific Safety Rules Work Area SafetyFunctional Description Grounding Grounded Tools Tools with Three Prong PlugsDouble Insulated Tools Tools with Two Prong Plugs Adjusting the Depth Gauge Fig Extension Cords Tool AssemblyGuidelines for Using Extension Cords Installing Bits FigOperation Maintenance AccessoriesFive Year Tool Limited Warranty Sécurité Individuelle Conserver CES InstructionsSécurité DU Lieu DE Travail Sécurité ÉlectriqueDescription Fonctionnelle Mise a LA TerreDirectives pour l’emploi des cordons de rallonge Calibres minimaux recommandés pour Les cordons de rallongeInstallation des forets Cordons DE Rallonge Montage DE LoutilManiement Maintenance Avertissement Accessoires AvertissementGarantie Limitée DE ’OUTIL DE Cinq ANS Seguridad Personal Guarde Estas InstruccionesSeguridad EN EL Área DE Trabajo Seguridad EléctricaSuministran con la herramienta. La TierraDescripcion Funcional Use los asideros auxiliares que seCómo colocar el medidor de profundidad Fig Extensiones Electricas Ensamblaje DE LA HerramientaGuías para el uso de cables de exten- sión Instalación de las brocas FigOperacion Mantenimiento de las herramientas Mantenimiento AdvertenciaAccesorios Advertencia Garantía Limitada DE Cinco AñosWest Lisbon Road Brookfield, Wisconsin, U.S.A Milwaukee800.729.3878 800.729.3878 fax