This manual explains the proper use of your new heat pump. Please read this manual carefully before using the product. This manual should be kept in a safe place for handy reference.

CONTENTS

•IMPORTANT SAFETY INSTRUCTIONS

1

•PART NAMES

2

•USING THE REMOTE CONTROL

4

•SETTING AIR PURIFYING FILTER

5

•TIPS ON SAVING ENERGY

5

•AUXILIARY MODE

5

•BASIC OPERATION

6

•ADJUSTING THE AIR FLOW DIRECTION

7

•COANDA AIRFLOW

8

•SPOT AIR

8

•FULL POWER OPERATION

9

•ENERGY SAVING OPERATION

9

•1.2.3.5h OFF TIMER

10

•TIMER OPERATION

10

•PLASMACLUSTER OPERATION

12

•SELF CLEAN OPERATION

12

•VACANCY OPERATION

13

•ADDITIONAL NOTES ON OPERATION

13

•MAINTENANCE

14

•BEFORE CALLING FOR SERVICE

15

•SPECIFICATIONS

15

 

IMPORTANT SAFETY

 

INSTRUCTIONS

WARNINGS FOR USE

1

This model should be installed with a fixed

power cord to the meter box.

2

Be careful not to expose your body to the outlet

air for prolonged periods. It may affect your

3

physical condition.

When using the unit for infants, children,

elderly, bedridden or disabled people make

 

sure the room temperature is suitable for those

4

in the room.

Never insert objects into the unit. Inserting

objects can result in injury due to the high

5

speed rotation of the internal fans.

If anything abnormal is noticed with the

air conditioner (eg burning smell), stop the

 

operation immediately and turn the circuit

6

breaker off.

This unit should be installed by a licensed heat

pump contractor in accordance with AS/NZS

 

3000 and your electricity suppliers service

7

rules.

There are local council rules regarding

maximum allowable noise levels emitted by

 

heat pump, your licensed heat pump contractor

 

will advise you on the correct location of your

8

outdoor unit.

If the supply cord is damaged, it must be

replaced by the manufacturer or its service

 

agent or a similarly qualified person in order

 

to avoid a hazard. Use only the manufacture-

9

specified power cord for replacement.

Do not pour water directly on the unit. Water

can cause electrical shock or equipment failure.

IMPORTANT SAFETY

INSTRUCTIONS

WARNINGS FOR INSTALLATION/REMOVAL/ REPAIR

For your safety, ensure that your new heat pump is installed by a licensed heat pump contractor in accordance with the AUSTRALIAN/NEW ZEALAND WIRING RULES.

Do not attempt to install/remove/repair the unit by yourself. Incorrect installation could cause electric shock, water leak, fire etc. Consult a licensed heat pump contractor for the installation/removal/ repair of the unit.

CAUTIONS FOR USE

1

If a gas appliance is used in the same room as

the heat pump, ventilate the room periodically

2

to prevent oxygen depletion.

For safety, do not touch the unit with wet hands,

it may cause an electric shock.

3

For safety, turn the circuit breaker off when not

using the unit for an extended period of time.

4

For safety, do not place anything on top of the

outdoor unit or step on it.

5

This unit is designed for residential use. Do not

use for other applications such as in a kennel

6

or greenhouse to raise animals or grow plants.

Do not block the air inlets or outlets of the unit.

It may result in degraded performance or unit

7

damage/failure.

For safety, be sure to turn the unit off at

the circuit breaker before performing any

8

maintenance or cleaning.

This appliance is not intended for use by young

children or infirm persons unless they have

been adequately supervised by a responsible person to ensure that they can use the appliance safely.

Young children should be supervised to ensure that they do not play with the appliance.

CAUTIONS FOR LOCATION/INSTALLATION

To ensure that your warranty is not affected, both the indoor/outdoor units and supply/interconnecting cables must be installed by a licensed heat pump contractor.

The unit is designed to operate on 220-240 VAC, 50Hz.

Do not install the unit where flammable gas may leak. It may cause a fire.

1

Image 3
Contents AY-ZP48LZ AE-Z48LZ Page Instructions ContentsImportant Safety Important Safety InstructionsPart Names Indoor UnitOutdoor Unit Transmitter Display Remote Control Remote Control DisplaySET Current Clock Time Using the Remote ControlHOW to USE the Remote Control Loading BatteriesSetting AIR Purifying FIL- TER Auxiliary ModeTips on Saving Energy To turn off the unit, press the Stop button Basic OperationPress the COOL, DRY or Heat button To change the fan speed, press the FAN buttonVertical airflow louvre will swing Adjusting the AIR Flow DirectionVertical AIR Flow Direction Horizontal AIR Flow Direction Press the Swing buttonPress the Coanda Airflow button again Coanda AirflowSpot AIR During operation, press the Coanda Airflow buttonPress the Energy Save button again Full Power Operation Energy Saving OperationDuring operation, press the Full Power button Press the Full Power button againPress the Timer OFF Button Timer OperationPress the 1.2.3.5h OFF Timer button to set the desired time Timer OFFCombined USE of on and OFF Timers Timer onTo Cancel Timer Mode To Change Time SettingDuring operation, press the Plasmacluster button Plasmacluster Operation Self Clean OperationPress the Self Clean button when the unit is not operating Press the Self Clean buttonPress the Heat button Press the Vacancy button Operating Temperature RangeVacancy Operation Additional Notes on OperationMaintenance Following conditions do not denote equip- ment malfunctions Before Calling for ServiceSpecifications Check the following points before calling for servicePage